Siemeca™ AMR
Pulse Adapter
The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 con-
sumption meters with pulse output and transmits the data to a Siemeca™ AMR
network. For setting the parameters, the pulse adapter is equipped with 2 inter-
faces, 1 wired interface and 1 optical interface.
The pulse adapter is a component of the Siemeca™ AMR system.
It is for installations where consumption meters with pulse output are used the data of
which shall be collected by the Siemeca™ AMR system. Such devices can be meters
for hot water, cold water, gas, electricity, etc.
Acquisition of the pulses delivered by the connected consumption meters
Monitoring the connecting cable in the case of metering devices with NAMUR circuit
Handling of pulses and storage of consumption data and set day values
Wireless transmission of data 6 times a day to the WT..16.. network nodes of the
Siemeca™ AMR system
2
AEW36.2
Building Technologies
873

Advertisement

loading

Summary of Contents for Siemens AEW36.2

  • Page 1 Pulse Adapter AEW36.2 The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 con- sumption meters with pulse output and transmits the data to a Siemeca™ AMR network. For setting the parameters, the pulse adapter is equipped with 2 inter- faces, 1 wired interface and 1 optical interface.
  • Page 2 Country-specific version AEW36.2/DK: Connection of 2 meters to the pulse adapter’s terminal block. Labeling in Danish. Ordering When ordering, please give type reference: AEW36.2 Equipment combinations When installing, the pulse adapter must be programmed with the data set delivered with the parameter setting software for the respective meter. If meters not contained in the meter data base shall be connected, a new data set must be requested.
  • Page 3 Consumption on the set day. This display alternates with the display showing the set day (notation: dd.mm). m³ If, during the pulse adapter’s operation, some other set day is programmed, the new set day appears here. Building Technologies Pulse Adapter AEW36.2 CE1N2873en 2016-02-12...
  • Page 4 Pulse acquisition channel 1 open-circuit Pulse acquisition channel 1 short-circuit Pulse acquisition channel 2 open-circuit Pulse acquisition channel 2 short-circuit Number of communication via IrDA exceeded Number of communication via M-bus exceeded Device not initialized Building Technologies Pulse Adapter AEW36.2 CE1N2873en 2016-02-12...
  • Page 5: Commissioning Notes

    Then, squeeze the connector with a pair of pliers. This connection cannot be separated and offers degree of protection IP54. Only for AEW36.2/DK: With the housing cover open, insert the meter connecting cables with the O-ring from the rear of the unit into the cable strain relief and connect the cables to the terminal block.
  • Page 6 For use in residential, commerce, light-industrial and industrial environments EU conformity (CE) CE1T2873xx Weight 0.3 kg Product environmental declaration (contains CE1E5383 data on RoHS compliance, materials com- po¬sition, packaging, environmental benefit, disposal) The documents can be downloaded from http://siemens.com/bt/download. Building Technologies Pulse Adapter AEW36.2 CE1N2873en 2016-02-12...
  • Page 7: Connection Diagrams

    Connection diagrams Connection of any type of meters with pulse output INP 1 INP2 AEW36.2 pulse adapter P1, P2 Meter with pulse output Connection of electricity meters with S0 inter- face INP 1 INP2 230 V AEW36.2 pulse adapter P1, P2 Electricity meters with pulse output N1, N2 WHZ.SO pulse converter...
  • Page 8 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 © Siemens Switzerland Ltd 2007 www.siemens.com/buildingtechnologies Delivery and technical specifications subject to change Building Technologies Pulse Adapter AEW36.2 CE1N2873en 2016-02-12...