Quick Links

Installation Instructions

Model XLS-MSE3(R)-ADPT
Adapter Kit
INTRODUCTION
DISASSEMBLY OF MXL -IQ SYSTEM
A6V10328636_en--_c
Use the Model XLS-MSE3(R)-ADPT Adapter Kit from Siemens Industry, Inc., to
upgrade existing MXL -IQ Systems installed in Model MSE-3L(R) or MSE-3M(R)
backboxes to FireFinder-XLS/Desigo Fire Safety Modular/Cerberus PRO Modular
Systems. The MSE-3L(R) and MSE-3M(R) will be referred to as MSE-3(R) in the
remainder of the document.
The XLS-MSE3(R)-ADPT Adapter Kit consists of an adapter plate, inner door and outer
door. The XLS-MSE3-ADPT (S54430-C14-A1) inner and outer doors are black; the
XLS-MSE3R-ADPT (S54430-C14-A2) inner door is black and outer door is red. The
XLS-MSE3-ADPT and the XLS-MSE3R-ADPT are identical in all other ways and will be
referred to in the remainder of this document as XLS-MSE3-ADPT.
The adapter plate installs over the existing studs in an MSE-3(R) backbox. The inner
door has an opening in it for the installation of a FCM2041-U2/-U3 operator interface
and either one ID-MP mounting plate or one ID-SP blank plate. The inner door is
permanently hinged right and is attached to the backbox by screws.
The XLS-MSE3(R)-ADPT is for indoor use only in dry environments.
With this conversion, the maximum battery set that can be used in the backbox is 18
AH (model BP-61). If larger batteries are required, use either a BB-55 or CAB-BATT
battery box.
To convert an MSE-3(R) backbox from an MXL -IQ System to an XLS/Desigo Fire
Safety Modular/Cerberus PRO Modular component system, you must first disas-
semble the MXL -IQ and then assemble the XLS/Desigo Fire Safety Modular/Cerberus
PRO Modular. This two-part procedure is described in detail below.
Remove all system power, first battery and then AC.
1.
Remove and discard the outer door. Reserve the hardware used to secure it
in place.
2.
Disconnect and remove the modules from the inner door.
3.
Remove all modules from the backbox, making sure to mark all wires.
Reserve the hardware used to secure them in place.
4.
Remove the MPS power supply and batteries from the backbox.
Siemens
Siemens
Siemens
Siemens Industry
Siemens
Industry
Industry
Industry, , , , , Inc.
Building
Building
Building
Building
Building T T T T T ec
ec
ec
echnologies Di
ec
hnologies Division
hnologies Di
hnologies Di
hnologies Di
Industry
Inc.
Inc.
Inc.
Inc.
vision
vision
vision
vision

Advertisement

loading

Summary of Contents for Siemens XLS-MSE3-ADPT

  • Page 1: Installation Instructions

    The XLS-MSE3-ADPT (S54430-C14-A1) inner and outer doors are black; the XLS-MSE3R-ADPT (S54430-C14-A2) inner door is black and outer door is red. The XLS-MSE3-ADPT and the XLS-MSE3R-ADPT are identical in all other ways and will be referred to in the remainder of this document as XLS-MSE3-ADPT.
  • Page 2 Adapter Plate The XLS-MSE3-ADPT adapter plate has holes in it that fit over the studs in the MSE-3 backbox in only one way. Place the XLS-MSE3-ADPT over the studs in the backbox and secure it in place with the hardware provided as shown in Figure 1.
  • Page 3 (Refer to Figure 3.) Adjust the door as needed so that it seats securely in the enclosure. MSE-3 BACKBOX LIP OF DOOR 8-32x5/16 SCREWS (QTY. 4) FLANGE LOCATION INNER OF OPTIONAL DOOR HTSW-1 TAMPER SWITCH Figure 3 Installing the Inner Door Siemens Industry, Inc. A6V10328636_en--_c Building Technologies Division...
  • Page 4 #10-32 hex nut (user supplied). Close the outer door and secure with the key latch. Siemens Industry, Inc. A6V10328636_en--_c Building Technologies Division...
  • Page 5 Non-Power Limited Wiring Wiring entering the enclosure from the bottom and right side of the backbox is considered non-power limited wiring. Wiring must be in the shortest route and must not overlap any other wiring. Siemens Industry, Inc. A6V10328636_en--_c Building Technologies Division...
  • Page 6 Pull all field wiring into the backbox. Do not dress the wiring until the location of all the equipment is known. Install the wiring from the external power source to the approximate location of the power supply. Siemens Industry, Inc. A6V10328636_en--_c Building Technologies Division...
  • Page 7 Cyber security disclaimer Siemens products and solutions provide security functions to ensure the secure operation of building comfort, fire safety, security management and physical security systems. The security functions on these products and solutions are important components of a comprehensive security concept.
  • Page 8 Siemens Industry, Inc. Siemens Canada, Ltd. P/N A5Q00054384 Document ID A6V10328636_en--_c Building Technologies Division 1577 North Service Road East Florham Park, NJ Oakville, Ontario L6H 0H6 Canada...

This manual is also suitable for:

Xls-mse3r-adpt