Download Print this page

Usage - Ivation Energy Star IVAESDH50WP User Manual

50-pint dehumidifier with pump (previously classified as 70-pint)

Advertisement

the nozzle until it is securely fastened.
4. Replace the water bucket as normal.
5. With the drainage hose passing through the bucket's drain
hole, aim the hose downward. Feed the other end of the hose
into a floor drain and cover the hole with a lid so the water will
run straight into the drain and not spill.
Please note that the hose should not be pressed, twisted, or
run up an incline, or else the water will not drain properly. See
diagram below.
NOTE: When you want to remove the drainage hose, you will need
to prepare a receptacle to collect water from the nozzle.
PUMP DRAINING
Note: The unit must be in PUMP mode for the pump to work. The
drainage pump will not run continuously but will turn on and off
as the float detects water in the bucket. Water will accumulate in
the bucket until the bucket is 90% full. At that point, the pump will
activate and drain the bucket to 75% full. Water will always remain
in the bucket even when pump draining is operating.
Installation
1. Push the gray rubber ring in and
remove the plug to open the pump
hose attachment.
2. Insert the included pump hose into
the pump hose attachment.
3. Run the drain hose to the location
where you want water to drain. The
pump can push water up to 16 feet (5 meters) horizontally or
vertically. Do not exceed this distance to avoid drainage or
device malfunctions.
Removal
1. Push the gray rubber ring in to open the
pump hose attachment.
2. While pushing the gray rubber ring in, pull
hard to remove the pump hose.
3. Once the pump hose is disconnected,
replace the plug and ensure the gray rubber ring goes back to
its normal position.
Note: When not using the pump drain option, leave the plug in
pump hose attachment port to prevent leaking.