MALFUNCTION CODES
Display
Malfunction
Code
Name
F1
Ambient
Temperature
Sensor
Malfunction
F2
Tube
Temperature
Sensor
Malfunction
F5
Discharge
Temperature
Sensor
Malfunction
L1
Humidity Sensor
Malfunction
F0
Freon-Lacking
Protection
H3
High-
Temperature
Overload
Protection
E4
High discharge
temperature
Symptoms
Possible Causes
Compressor and
• Ambient temperature sensor
fan motor have
is loose or is poorly connected
stopped. The
to the display board terminal.
buttons on the
• An element of the display
control panel do
board may have been installed
not work.
upside down and short-
circuited.
• Ambient temperature sensor is
damaged.
• Display board is damaged.
• Temperature sensor on the
evaporator is loose or poorly
connected to the display
board terminal.
• An element of the display
board may have been installed
upside down and short-
circuited.
• Temperature sensor on the
evaporator is damaged.
• Display board is damaged.
• Temperature sensor on the
evaporator is loose or poorly
connected to the display
board terminal.
• An element of the display
board may have been installed
upside down and short-
circuited.
• Display board is damaged.
• Humidity sensor is short-
circuited.
• Humidity sensor is damaged.
• Display board is damaged.
The compressor
• Refrigerant is leaking.
stops and the
• Unit is blocked.
fan motor
• Ambient operating conditions
stops after 30
are poor.
seconds.
• Evaporator and condenser are
blocked by dirt/dust.
The compressor
• Device has encountered an
stops and the
abnormal condition (blockage,
fan motor
etc.)
stops after 30
• Motor rotation speed is
seconds.
abnormal.
• Air intake is obstructed.
• Compressor discharge
temperature sensor is
damaged or poorly connected.