Thank you for purchasing the Ivation® 95-Pint Dehumidifier with Built-in Pump. This User Guide is intend-
ed to provide you with guidelines to ensure that operation of this product is safe and does not pose risk to
the user. Any use that does not conform to the guidelines described in this User Guide may void the limited
warranty.
Please read all directions before using the product and retain this guide for reference. This product is
intended for household use only. This product is covered by a limited one-year warranty.
Coverage is subject to limits and exclusions. See warranty for details.
Features
• Removes up to 95 pints (approximately 11.9 gallons/45L) of moisture from the air per day
• Meets ENERGY STAR® specifications
• Removable, cleanable filter
• Adjustable humidity control 35% — 85%
• 2-speed fan
• 24-hour timer
• Full reservoir alert
• Auto defrost
• Auto shutoff
• Auto restart
• Built-in drainage pump
• Direct drain option for continuous operation
• Casters for easy portability
ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the
U.S. Environmental Protection Agency.
ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.

Advertisement

Table of Contents
loading

Summary of Contents for Ivation IVALDH95PWWP

  • Page 1 USER GUIDE IVALDH95PWWP Thank you for purchasing the Ivation® 95-Pint Dehumidifier with Built-in Pump. This User Guide is intend- ed to provide you with guidelines to ensure that operation of this product is safe and does not pose risk to the user.
  • Page 2: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. • Use this product only for its intended purpose. • This unit is designed to operate in an environment of 41°F (5°C) — 96°F (35°C). •...
  • Page 3: Correct Placement

    Correct Placement Place the unit with proper clearance from walls, furniture, or window coverings. Place the unit on a hard, level surface. Close doors and windows in the room where the dehumidifier is operating. AIR OUTLET 20" OR MORE AIR INTAKE 10"...
  • Page 4 Parts and Functions (Illustrations for demonstration purposes only. Your unit may look slightly different.) CONTROL PANEL HANDLE MOIST AIR INTAKE DEHUMIDIFIER DRY AIR VENT WATER COLLECTION RESERVOIR AIR FILTER POWER CORD HOLDER CONTINUOUS DRAINAGE OUTLET ROLLING CASTERS PUMP DRAIN HOSE OUTLET POWER CORD 20"...
  • Page 5: Control Pannel

    Control Pannel HUMIDITY/ TIMER TIMER ON AND OFF AUTO DEFROST ON RESERVOIR FULL RH% AND TIMER TIMER BUTTON INDICATOR LIGHT INDICATOR LIGHT INDICATOR LIGHT DISPLAY CONTROL BUTTON CONTINUOUS OPERATION INDICATOR LIGHT POWER BUTTON CONTINUOUS BUTTON PUMP OPERATION INDICATOR LIGHT TURBO FAN INDICATOR LIGHT COMFORT DEHUMIDIFYING OPERATION INDICATOR LIGHT...
  • Page 6: Automatic Features

    3. Filter Button The filter LED light will illuminate after approximately 250 hours of operation to remind you to clean the air filter to obtain maximum performance and efficiency. To reset after cleaning the filter, press the Filter button and the light will go off. 4.
  • Page 7: Error Codes

    Error Codes The following codes may appear on the LED display: Error Codes AS - Humidity Sensor Error Unplug the unit and plug it back in. ES - Temperature Sensor Error Unplug the unit and plug it back in. P2 - Water Collection Reservoir is full Empty the reservoir.
  • Page 8: Removing Collected Water

    2. Press the Timer button. The Timer On indicator light will illuminate. This indicates that the Auto Start function is initiated. (If you press the Timer button again, the Timer Off indicator light will illuminate.) 3. Press or hold the left < and right > buttons to enter a time interval between 0.0 and 24 hours. Time will increase or decrease in 0.5 hour increments up to ten (10) hours, and thereafter in one (1) hour increments up to 24 hours.
  • Page 9 2. Continuous Draining (Gravitational) Water can be automatically emptied into a floor drain by attaching a hose with a female threaded end (not included) to the continuous drain hose. a) Remove the plastic cover from the drain outlet in the back of the unit. Water may drip from the outlet if the dehumidifier was previously used.
  • Page 10: Care And Maintenance

    NOTE: Do not use this feature when the outdoor temperature is equal to or less than 32°F (0°C) as discarded water may freeze and damage the unit. NOTE: In the event of a malfunction, the pump operation light will blink. Turn off the unit and unplug it from the power source.
  • Page 11: Troubleshooting

    Troubleshooting Problem Possible Causes Make sure the power cord and plug are not damaged and that the plug is pushed completely into the wall socket. Check the fuse/circuit breaker box. Unit does not start Reservoir may be full. Reservoir not in the proper position. Unit has cycled off because the desired humidity level has been reached.