Allowing Computer Access To Your System; Language Selection - DSC Power Series Manual

Hide thumbs Also See for Power Series:
Table of Contents

Advertisement

DSC Power Series PC1616 PC1832 PC1864 System Manual
1. Prior to testing, ensure that the system is disarmed and the Ready light is on.
2. Press [#] and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion
detector areas).
PK5500/LCD5500 keypads will display the following message when each zone (detector) is activated:
"Secure System Before Arming < >", "Secure System or Enter Code" or "Secure or Arm System". Use the [<
>] keys to view which zones are open. The message will disappear when the zones are closed.
On an PK5501/LCD5501Z keypad, the display says "Open" when any zone (detector) is activated. To see
which zones are open, press [#]. The keypad will scroll the numbers of all open zones.
On a PK5508/PK5516/PC55XXZ keypad, the zone light turns on when the zone (detector) is activated. The
zone light turns OFF when the zone is closed (e.g., door or window closed).
Note: Some features described above will not be functional unless enabled by your installer. Ask your
installer which features are functional on your system.
Walk Test Mode
The installer can initiate a Walk Test mode for the system. While in Walk Test mode, The Ready, Armed,
and Trouble LED's will flash to indicate that Walk Test is active. When the system automatically terminates
the Walk Test modes, it will annunciate with an audible warning (5 beeps every 10 seconds), beginning
five minutes prior to the termination of the test.

Allowing Computer Access to Your System

From time to time, your installer may need to send information to or retrieve information from your
security system. Your installer will do this by having a computer call your system over the telephone line.
You may need to prepare your system to receive this 'downloading' call. Press [*][6][Master code][5] at
any keypad. This allows downloading for a limited period of time. During this time, the system will answer
incoming downloading calls.
To learn more about testing your system, please visit
Other System Information

Language Selection

Your keypad may have the capability to display messages in different languages.
1. Press and hold both [< >] keys simultaneously.
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]
System Testing

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc1616Pc1832Pc1864

Table of Contents