• Never run the circulati ng pump (depending on the model) without water. The circulati ng
pump is very quiet when it starts up; you may not hear it running.

3.1 I Operati ng principle

Your heat pump uses the calories (heat) from your home's heati ng to heat up your pool's water.
The heat is exchanged through a series of pipes; the home's heati ng water circulates through the exchanger's body and
the pool water circulates through the pipes.
Tips: improve your pool's temperature rise and maintenance
Cover the basin with a sheet (bubble canopy, canvas, etc.) to prevent heat loss. The closer the heat source
is to the exchanger, and the exchanger is to the pool, the less heat will be lost.
Anti cipate the commissioning of your pool far enough in advance before you use it.
For the temperature rise, set the fi ltrati on pump to conti nuous operati on (24/24).
To maintain the temperature throughout the season, run "automati c" circulati on for at least 12 hours/
day (the longer this ti me the longer the appliance will have enough operati ng range to heat up)

3.2 User interface presentati on (depending on the models)

Display screen (default: water temperature measured)
"On/off " butt on
Value setti ng butt ons
"On/off "
Heati ng light
Tips: using the user interface
The temperature is regulated by degrees.
Hold down the butt ons to scroll through the values quickly.
The setpoint adjustment range is between 2° and 40°C.
This maximum temperature may be lowered to protect the pool liner (see § "3.2.1 Modifying the
maximum setpoint").
3.2.1 Modifying the maximum setpoint
Switch off the regulator (the "on" light goes off and the pool water temperature is displayed),
Press
and
Press
, then enter the value "80" with
Press
to confi rm: "PA" is displayed,
Press
and
Press
to scroll through each parameter unti l "r2" is displayed,
Press
; the current "r2" parameter value is displayed,
Press
or
Press the
and
8
❸ Use
Fixed
Appliance
light
powered up
Heati ng in
progress
simultaneously for 5 seconds: "PA" is displayed,
or
simultaneously for 5 seconds: "/1" is displayed,
to modify the maximum setpoint value, then press
keys at the same ti me for 5 seconds to return to the pool water temperature display.
Flashing
/
Timed before operati on
No water circulati on in the secondary
circuit (less than 1.1m³/h)
(code to access the "parameters" menu),
to validate this new value,
Off
No electrical
supply
No need for
heati ng
H0360800.D - EN - 2016-02