2.1 I Selecti ng the locati on

• The appliance must be installed in a technical room venti lated, dry and without stored pool
treatment products.
Install the appliance as close as possible to the heati ng source (boiler, heat pump, geothermal, solar-powered heati ng,
etc.),
If the appliance cannot be installed beside the heati ng source:
- Provide for the dimensioning of the pipes and primary and secondary circuits in relati on to the water fl ow rate, the
losses of load and the distance, and insulate them thermally,
- Install a more powerful circulati ng pump (contact us for its dimensions and supply),
If the exchanger is located far from the fi lter: The pipes of the pool system must be Ø50, or Ø63 if the system has an
overall length in excess of 30 meters, and must be routed through a protecti ve conduit if buried.
Preferably, the exchanger should be installed at the low point so that it is always full of water.
The water treatment system must be installed aft er the exchanger and at a low point to avoid chlorine being returned
to the exchanger,
Leave at least 80 cm free space around the appliance to facilitate its installati on and maintenance,
The pipes must not be supported by the exchanger.
The appliance must be secured horizontally to the wall of the technical compartment:
- Heat Line N: using brackets (not included).
- Heat Line + and SC: using the holes at the back of the electric box and 4 screws (not included).
Dimensions for Heat Line + and Heat Line SC att achment