Table of Contents GX300 Table of Contents About this manual ......................5 How to work with the manual ..................5 Record of changes …………………………………………………………………………….. 5 Safety..........................6 Intended use ........................6 Liability ........................... 6 2.2.1 General liability....................6 2.2.2 Machine-specific liability ..................6 User qualification for installation ..................
Page 4
Table of Contents GX300 Installation ........................19 Unpack the machine ..................... 19 4.1.1 Remove the cardboard ..................19 4.1.2 Remove the protection and foil ................. 19 4.1.3 Remove the transport brackets ................. 20 Put the machine in position ..................20 4.2.1...
The GX300 and all its versions are referred to in the manual as the 'machine'. This manual contains the original instructions. The original language of the manual is English. All other language versions are translations of the original instructions.
Safety GX300 Safety WARNING Read the manual before you install or use the machine. Failure to do so can result in personal injury, death or property damage. Intended use The machine is designed to mix paint in a can. Any other use of the machine is strictly forbidden.
Safety GX300 Personal harm should be avoided by strictly following the materials safety data sheets (MSDS) for colorants and (base) paint. The use of flammable colorants or colorants that diffuse potential explosive vapors may present fire and explosion risks. User qualification for installation Only install the machine when you are a qualified service technician who is trained and certified by Fast &...
Safety GX300 Safety symbols in the manual WARNING WARNING Can cause personal injury. Pinch hazard. CAUTION Note Can cause damage to the machine. Shows further information. Disposal of the machine 1. Sort the machine, the accessories and the packaging for environmentally friendly recycling.
Operator manual GX300 Operator manual Description 3.1.1 Overview of the machine A: Can Plate (Top) E: Emergency Switch I: Drain Orifice B: Can Plate (Bottom) F: Control Panel J: Can Table C: Door G: Casing K: Net Entry D: Top Cover...
Operator manual GX300 3.1.2 Overview of the control panel A: Emergency stop switch B: Program keys. Note The display shows the program menu with the multiple functions of the program keys. 3.1.3 Overview of the program keys Ready for use When the machine is ready for use, the display shows the available programs.
Page 11
Operator manual GX300 Choose the mix time Key pushed Mix time [s] Note The table shows the default values.
Operator manual GX300 3.1.4 Type plate: serial number Operation WARNING Only push the emergency stop switch in case of a safety emergency. 3.2.1 Turning on the machine - if the cradle is in the correct position 1. Connect the power cable to the grounded wall socket.
Operator manual GX300 3.2.3 Turning on the machine when the machine is in hibernation When the machine is in hibernation, the door is locked & display shows ‘.’ (one dot). 1. Push any key to unlock the door. When the machine is operational, the display shows ‘RDY’.
Operator manual GX300 3.2.5 Placing the can Pull out the can table 1. Open the door. 2. Pull up the handle (A) to unlock the can table (B). 3. Pull out the can table until you hear a 'click'. The can table is locked.
Operator manual GX300 2. If the can plates are too close to each other, move the can plates manually. See § 3.2.8. Retain the can handle 1. If you place one can, make sure that the can handle (A) cannot move. Use elastic band(B) or stick the can handle with strong glue tape.
Operator manual GX300 3.2.7 Remove the can 1. Wait until you hear a 'beep' and the display shows 'RDY!' The door is unlocked. 2. Open the door. 3. Pull up the handle (A) to unlock the can table (B). 4. Pull out the can table until you hear a 'click'. The can table is locked.
Operator manual GX300 3.2.10 Mixing speed during operation Speed: 15cm and lower can height = 230rpm 30cm and higher can height = 130rpm 3.2.11 Stop the operation manually 1. Push the Stop/Up key. 2. Wait until you hear a 'beep' and the display shows 'RDY !' The door is unlocked.
Operator manual GX300 Maintenance 3.3.1 General safety instructions for maintenance WARNING Check the MSDS of the colorants about personal protection measures required for handling the colorant. CAUTION Do not use cleaning agents based on organic solvents to clean the machine.
Installation GX300 Installation Unpack the machine 4.1.1 Remove the cardboard 1. Remove the tensioning straps (A). 2. Remove the cardboard (B). 4.1.2 Remove the protection and foil 1. Remove the plastic foil (A).
Installation GX300 4.1.3 Remove the transport brackets 1. Remove the screws (A). 2. Remove the transport brackets (B). Put the machine in position 4.2.1 Put the machine in position 1. Loosen the nuts (C) of the adjustable feet(B). 2. Move up the adjustable feet until the wheels (A) are on the round.
Installation GX300 4.2.2 Make a ramp of the pallet 1. Remove the screws. 2. Remove the pallet beam. 4.2.3 Move the machine from the pallet 1. Move the machine 2. Roll the machine on the floor...
Installation GX300 Move the machine in position 4.3.1 Move the machine to the final location WARNING Mind the minimum requirement of the load capacity of the floor. See § 6.2. CAUTION Do not use a fork-lift truck. Note Make sure that the final location is well-lit and well- ventilated.
Troubleshooting GX300 Troubleshooting General troubleshooting procedure 1. Try to solve the problem with the information in this manual. See § 5.3.1. 2. If it is not possible to solve the problem with the information in this manual, contact service. See § 5.3.
Troubleshooting GX300 5.4.1 Easy-to-solve errors Problem Possible cause Possible solution The display shows 'E01' The door is open. Close the door. The cradle lock failed to release The display shows 'E05' Restart the machine. See § 3.2.13. the cradle. Emergency stop switch is pushed Release the emergency stop switch.
Troubleshooting GX300 5.4.4 Software errors Problem Possible cause Possible solution The display shows 'F00' Parameter is not available. Contact service. See § 5.3. The display shows 'F54' Invalid state value. Contact service. See § 5.3.
Technical data GX300 Technical data General specifications Parameter Specification Materials used are suitable for Water, universal and solvent colorants Maximum load weight [kg] Can plate dimensions [cm] Can plate bottom seating diameter [cm] Maximum can height [cm] Minimum can height [cm]...
Technical data GX300 Noise level Parameter Specification Maximum noise level [dB(A)] < 78 Safety classifications Parameter Specification IP (Ingress Protection) classification EMC (ElectroMagnetic Compliancy) classification Class B Overvoltage category Class II Electrical specifications Parameter Specification Power consumption, maximum [W] 1000...