Air Hose Connection - Pace DUAL THERMOPIK DTP-80 Operation & Maintenance Manual

Handpiece
Table of Contents

Advertisement

AIR HOSE CONNECTION

Use the following procedure to attach the handpiece air hose to your PACE power
source.
Ensure that only one air hose is connected to the AUTO SNAP-VAC (or
SNAP-VAC) or Controllable PRESSURE Port at one time. Attachment
to both ports simultaneously will cause a deterioration of performance.
To set up your DTP-80 for operation, perform the following steps:
1. Connect the 152 cm (60 inch)
length of black silicone air hose
to the Vacuum Pick tube (metal
tube) in the middle of the
handpiece.
2. Attach the male quick connect
hose mount fitting (P/N 1259-
0102) supplied with the
handpiece to the other end of
the black silicone air hose. This
fitting has a special Vacuum
Release Opening to provide a
quick component release during
component removal operations;
DO NOT use any other male
fitting.
3. Secure the air hose to the
handpiece power cable with
hose clamps (P/N 1321-0274).
8