Download Print this page

ADTRAN HDSL4 Quick Start Manual page 2

Hide thumbs Also See for HDSL4:

Advertisement

ADTRAN HDSL4 equipment is designed with troubleshooting-at-a-glance features. The following information
provides suggestions for troubleshooting as a result of LED indications which are indicative of loop trouble.
Note: Pressing "ESC" while on any screen will go back to the previous screen.
INDICATIONS AND POSSIBLE CAUSES
DSL LED Yellow
Connect a terminal or PC to the RS-232 (DB-9) craft interface on faceplate. The terminal must be VT100 or
compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, No Flow control. Select "3" from the
ADTRAN HDSL4 Main Menu Screen and "1" from the Span Status Screen. Verify the following conditions on the
Detailed HDSL4 and T1 Status Screen:
Margin ≥ 6 dB
Pulse Attenuation ≤ 35 dB (1st segment)
Pulse Attenuation ≤ 31 dB (2nd segment)
No ES, SES, or UAS (Performance History
Screen, Main Menu Selection 5)
If the above conditions do exist, the circuit should
provide quality service; however, if any of the above
conditions do not exist, a cable problem or excessive
loss situation is probable, and more detailed cable
testing should be done to verify all HDSL4 Loop
Specifications are met. These conditions may also
reflect intermittent cable faults or excessive noise
impairments. If intermittent faults or noise impairments are suspected, review the Performance History Screen.
HDSL4 DEPLOYMENT GUIDELINES
The first segment of the circuit is defined as the section of the HDSL4 loop between the H4TU-C and the first H4R,
the second segment is between the first H4R and the second H4R (dual repeater designs) or between the H4R and
the H4TU-R (single repeater designs), and the third segment is between the second H4R and the H4TU-R.
NOTE: If dual repeaters are used in the circuit, please refer to the "HDSL4 Deployment Guidelines"section of the Installation
and Maintenance Practice for DC resistance guidelines for span powering.
Margin ≥ 6 dB
Pulse Attenuation ≤ 35 dB (1st segment)
Pulse Attenuation ≤ 31 dB (2nd/3rd segment)
All loops are nonloaded
Any single bridge tap is limited to 2 kft
Total bridge tap length is limited to 2.5 kft
Loop length up to 16 kft (24 AWG) on circuit containing no H4Rs
Loop length up to 16 kft first segment and 15 kft second segment (24 AWG) on circuit containing one H4R
Loop length up to 13.5 kft first segment, 14 kft second segment, 15 kft third segment (24 AWG) on circuit containing
two H4Rs
First segment (or a circuit containing no H4Rs) Insertion Loss ≤ 46 dB
Second and third segment Insertion Loss ≤ 42 dB
Maximum loop resistance is 1150 Ohms for circuits without an H4R.
Impulse Noise =50 dBrn as measured using a 50 kb filter
Wideband Noise =31 dBrn as measured using a 50 kb filter
Foreign Voltage DC (t-r, t-g, r-g) < 3 VDC
Insulation Resistance (t-r, r-g, t-g) > 3.5 M
Longitudinal Noise (Power Influence) < 80 dBrnC
HDSL4 TROUBLESHOOTING GUIDE
LOOPBACK AND CONTROL CODES
Pattern
D3D3
D5D5
D5D6
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer's order for use in the
U.S. is ten (10) years. For a complete faxback copy of ADTRAN's U.S. and Canada Carrier Networks Equipment
Warranty (P/N 60000087-10), call: (877) 457-5007, document #414.
Description
1in3
Loop down all units and disarm
2in5
Arming Pattern, HTU-R will loop up if Smartjack LB is enabled
3in5
Disarm and loop down all units. Restores LB TMO after D5D6
1in6
Network Arming Pattern. If Smartjack LB is Enabled, HTU-R will loop toward Network.
2in6
H4R LB to Network
3in6
H4R LB to Network
4in6
H4R LB to Customer
5in6
H4R LB to Customer
3in7
H4TU-R LB to Network
4in7
H4TU-C LB to Network
5in7
H4TU-R LB to Customer
6in7
H4TU-C LB to Customer
3F1E
H4TU-C LB to Customer
3F02
H4TU-R LB to Customer
3F04
H4R LB to Customer
3F06
H4R LB to Customer
6767
Disable span powering while present
9393
Loop down HTU-C, Repeaters - all loopbacks. Loop down H4TU-R - Cust LB always.
Will only loop down HTU-R Net LB if NIU is disabled. Does not Disarm units if they are armed.
C741
H4R #1 loop up pattern. 10 bit error injection.
C742
H4TU-R loop up pattern. 20 bit error injection.
C754
H4R #2 loop up pattern. 200 bit error injection.
H4TU-C loop up pattern. 231 bit error injection.
Query Loopback Pattern (error injection)
H4TU-C: 231 Errors, H4R #1: 10 Errors, H4R #2: 200 Errors, H4TU-R: 20 Errors
Loopback Timeout Override: Disables LB timeout. Restores original LB timeout when unit is
disarmed.
FF48
FDL Arming Pattern (ESF only). Arms all units, H4TU-R will LB to Network if NIU Enabled
(if pattern sources at network).
FF24
FDL Disarm Pattern (ESF only). Loop down and disarm all units
FF1E
H4TU-C LB to Network. Will not loop up H4TU-C if H4TU-C already in LB to Customer.
FF02
H4TU-R LB to Network. Will not loop up H4TU-R if any unit already in LB to Customer.
FF04
H4R LB to Network
FF06
H4R LB to Network
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61221424L1-22A
Requires Arming?
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No

Advertisement