  • Page 1 Embedded Computing for Business-Critical Continuity Centellis 2000 User Card-10GE Installation and Use P/N: 6806800H33B December 2012...
  • Page 2 Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
  • Page 3: Table Of Contents

    Centellis 2000 User Card-10GE Hardware ........
  • Page 4 Related Documentation ............. . . 43 Emerson Network Power - Embedded Computing Documents ......43 Related Specifications .
  • Page 5 Centellis 2000 User Card-10GE Specific Sensors ....... . . 32...
  • Page 6 List of Tables Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 7 List of Figures Figure 1-1 Functional Block Diagram of the Centellis 2000 Chassis ..... . 16 Figure 1-2 Overview ............. . 17 Figure 1-3 Block Diagram .
  • Page 8 List of Figures Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 9: About This Manual

    This manual is intended for users qualified in electronics or electrical engineering. Users must have a working understanding of AdvancedTCA and telecommunications. This manual provides the information you need to install, access and operate the Centellis 2000 User Card- 10GE. Additionally you need the System Management Interface Based on HPI-B (Centellis CO 31kX/4100/2000) User’s Guide to adopt the hardware platform interface.
  • Page 10 International Electric Code Internet Protocol Intelligent Platform Management IPMB Intelligent Platform Management Bus IPMC Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface Light Emitting Diode LVDS Low Voltage Differential Signal Media Access Control Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 11 Restriction of the use of Certain Hazardous Substances Rear Transition Module Software Availability Forum SELV Safety Extra Low Voltages Shelf Manager Small Form-factor Pluggable Underwriters Laboratory Inc. VCCI Voluntary Control Council for Interference Virtual IP Address Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 12 Repeated item for example node 1, node 2, ..., node Omission of information from example/command that is not necessary at the time being Ranges, for example: 0..4 means one of the integers 0,1,2,3, and 4 (used in registers) Logical OR Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 13 Indicates a property damage message No danger encountered. Pay attention to important information Summary of Changes Order No. Date Description 6806800H33A September 2010 First edition 6806800H33B December 2012 Updated Chapter 1, Standard Compliances, on page Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 14 About this Manual About this Manual Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 15: Introduction

    IPMBs and accesses one Fabric Interface (FI) of the corresponding AdvancedTCA blade. The Centellis 2000 User Card-10GE module is intended to be used in a CENT-2000 chassis. The module when installed in the dedicated User Card slot provides uplink connectivity from the payload Ethernet fabric channel.
  • Page 16 XAUI 10G Ethernet interface which is converted by the 10G User Card to a serial 10G Ethernet interface on an SFP+ module. Figure 1-1 Functional Block Diagram of the Centellis 2000 Chassis Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 17: Hardware

    Introduction Hardware The following figure gives an overview about the main parts of the board. Figure 1-2 Overview Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 18 Introduction Figure 1-3 Block Diagram Functional Characteristics: Transceiver — BCM8706 10GE Serial-to-XAUI 10GBASE-LRM transceiver — Compliant to IEEE 802.3ae and IEEE 802.3aq Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 19: Standard Compliances

    Dual +3.3V management power sourced via backplane — Local power generation of +5.0V, +3.3V and +1.0V Power on reset generation and power supervision Standard Compliances The Centellis 2000 User Card-10GE, when installed in a compliant chassis, meets the following standards: Table 1-1 Standard Compliances Standard Description...
  • Page 20: Ordering Information

    (RoHS) Directive 2011/65/EU. For Declaration of Conformity, refer Centellis 2000 User Card Declaration of Conformity. Ordering Information The table below shows the board's ordering information. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 21: Table 1-2 Ordering Information

    Introduction For further details please contact your local Emerson representative. Table 1-2 Ordering Information Order No. Name Description CENT-2000-UC-10GE CENT-2000 10GE USER CARD Centellis 2000 uplink card without SFPP MODULE Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 22 Introduction Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 23: Centellis 2000 User Card-10Ge Hardware

    Chapter 2 Centellis 2000 User Card-10GE Hardware Overview The Centellis 2000 User Card-10GE is compliant to PICMG 3.0 R3.0 (AdvancedTCA). The shelf manager and hub board is equipped with two backplane connectors. Figure 2-1 Hardware To prevent connector damage the alignment pin offers a guide rail to the slot and a coding mechanism to ensure the installation of the board in the matching slot.
  • Page 24: Payload Hardware

    Handle switch and status LED interface to the face plate Power supply Payload Hardware The payload hardware of the Centellis 2000 User Card-10GE is always powered when power supply is present. The following interfaces are available: Fabric 2 ethernet interface to payload slot SFP+ 10GE ethernet interface resident on the front panel 2.2.1...
  • Page 25: Ipmb0 Interface

    The Centellis 2000 User Card-10GE has no provisions to switch off the power input. The board is powered whenever the power is attached to the Centellis 2000 system (-40 VDC to -72 VDC). The board satisfies the standby power limit of 10 W for AdvancedTCA FRUs. Typical power consumption of the Centellis 2000 User Card-10GE board is 2.8 W.
  • Page 26: Power Supply Holdup

    2.4.2 Power Supply Holdup The Centellis 2000 User Card-10GE complies with the requirements for board level voltage transients as described in chapter 4.1.4.3. of PICMG 3.0 (AdvancedTCA) specification. It satisfies the requirement of uninterrupted operation during a power failure of 5 ms.
  • Page 27: Installing An Sfp/Sfp+ Module

    Installing an SFP/SFP+ Module Procedure In order to install an SFP/SFP+ module, proceed as follows: 1. Slide the SFP/SFP+ module into the slot until it locks into position. 2. Remove the optical port plug. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 28 Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. 3. Connect the network cable to the SFP/SFP+ module. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 29: Removing An Sfp/Sfp+ Module

    1. Remove any connected cable from the SFP module. 2. Open the SFP/SFP+ latch. Note that the latch mechanism of your SFP/SFP+ module may be slightly different compared to the latch shown in the following figure. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 30: Frame Ground And Esd

    The face plate mounting holes of the board are connected to frame ground. An ESD strip according to the AdvancedTCA specification PICMG 3.0 R3.0 is provided at one edge of the PCB. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 31: Controls, Indicators And Connectors

    The following LEDs can be found on the face plate of the board. OOS, OK and H/S are ATCA LEDs and can be controlled via IPMI. For more information, see the Centellis 2000 User Card-10GE: Control via IPMI Programmer’s Reference manual.
  • Page 32: Ethernet Connectors

    The IPMC functionality is based on the IPMI specification V1.5. The IPMI sensors on the Centellis 2000 User Card-10GE are shownTable 3-2. For further information, see the Centellis 2000 User Card-10 GE: Control via IPMI Programmer’s Reference. Table 3-2 Centellis 2000 User Card-10GE Specific Sensors...
  • Page 33 +3.3V sensor VOLTAGE_5_0 Voltage (02h) +5.0V sensor Threshold (1) TEMPERATURE0 Temperature (01h) Temperature Threshold (1) sensor 0 TEMPERATURE1 Temperature (01h) Temperature Threshold (1) sensor 2 SFP_TEMPERATURE Temperature SFP Temperature Threshold (1) (01h) sensor Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 34 Controls, Indicators and Connectors Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 35: Board Exchange

    Chapter 4 Board Exchange Introduction This chapter describes how to install the Centellis 2000 User Card-10GE board and includes the following information: Before installation Installing the board in a shelf Starting up the board Removing the board Operation The system is shipped with pre-installed Centellis 2000 User Card-10GE boards. You have to observe the following procedures when ordering a board as a spare part or exchanging a board.
  • Page 36: Environmental Requirements

    5-20 Hz at 0.01 g in target at a rate of 0.1 octave/minute. 20-200 Hz at -3.0 dB/octave platform) Random 5-20 Hz at 1 m /Sec Random 20-200 Hz at -3 dB/octave Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 37: Power Requirements

    Make sure that the board is used in Centellis 2000 AdvancedTCA shelf. If the module is used in a Centellis 2000 DC version shelf, make sure it is connected to -48 VDC up to -60 VDC (rated voltage), according to Telecommunication Network Voltage (TNV-2).
  • Page 38: Required Equipment

    Shipment Inspection To inspect the shipment, perform the following steps: 1. Verify that you have received all items of your shipment: Printed Safety Notes Centellis 2000 User Card-10GE Any optional items ordered Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 39: Installing The Board

    Before touching boards or electronic components, make sure that you are working in an ESD-safe environment or wear ESD wrist straps. The board must only be operated in a shelf that is properly grounded. To install the board into an AdvancedTCA shelf, proceed as follows. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 40: Removing The Board

    The switched off blue LED indicates that the board is activated. 8. Attach cables to the front panel connectors as necessary. Removing the Board This section describes how to remove the board from an AdvancedTCA system. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 41 "extraction pending", so that the blue LED is still blinking. 6. Wait until the blue LED is illuminated. 7. Remove the board from the shelf using the extraction handles. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 42 Board Exchange Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 43: Related Documentation

    Technical Documentation Search. This site provides the most up-to-date copies of Emerson Network Power - Embedded Computing product documentation. Check the Emerson literature catalog for errata sheets that may be applicable to the board. Table A-1 Emerson Network Power - Embedded Computing Publications...
  • Page 44 Related Documentation Table A-2 Related Specifications (continued) Organization Document Title Service Availability Forum Service Availability Forum Hardware Platform Interface http://www.saforum.org SAI-HPI-A01.01 Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 45: Safety Notes

    Emerson intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
  • Page 46 Changes or modifications not expressly approved by Emerson could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements.
  • Page 47 Therefore, only install it in or remove it from a powered system if the system itself supports hot swap or high availability and if the system documentation explicitly includes guidelines. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 48 Safety Notes Replacement/Expansion Only replace or expand components or system parts with those recommended by Emerson. Otherwise, you are fully responsible for the impact on EMC or any possible malfunction of the product. Check the total power consumption of all components installed (see the technical specification of the respective components).
  • Page 49: Sicherheitshinweise

    Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht garantieren. Falls Sie weitere Informationen benötigen sollten, wenden Sie sich bitte an die für Sie zuständige Geschäftsstelle von Emerson. Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf ausschließlich für Anwendungen in der Telekommunikationsindustrie und im Zusammenhang...
  • Page 50 Sicherheitshinweise Das Produkt wurde in einem Emerson Standardsystem getestet. Es erfüllt die für digitale Geräte der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen angemessenen Schutz vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie Industriegebieten...
  • Page 51 Betreiben Sie das Board nur innerhalb der angegebenen Grenzwerte für die relative Luftfeuchtigkeit und Temperatur. Stellen Sie vor dem Einschalten des Stroms sicher, dass sich auf dem Board kein Kondensat befindet. Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 52 System Hot Swap oder High-Availability unterstützt und wenn die Systembeschreibung dies ausdrücklich erlaubt. Austausch/Erweiterung Verwenden Sie bei Austausch oder Erweiterung nur von Emerson empfohlene Komponenten und Systemteile. Andernfalls sind Sie für mögliche Auswirkungen auf EMV oder Fehlfunktionen des Produktes voll verantwortlich.
  • Page 53: Index

    Ethernet connector power Ethernet interfaces input exchanging the board supply power requirements face plate power supply feedback external frame ground onboard hardware 21, requirement payload environmental interface sensor shelf management controller Ethernet IPMB0 Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 54 Ethernet connector power requirements exchanging the board power supply external onboard face plate frame ground requirement environmental hardware payload sensor shelf management controller interface IPMB0 shelf management controller IPMB0 interface Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 55 Index Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 56 Index Centellis 2000 User Card-10GE Installation and Use (6806800H33B)
  • Page 58 Precision Cooling Surge & Signal Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. All other product or service names are the property of their respective owners.

Table of Contents