Communication Ports
4.1 Copper Ethernet Ports
Electric shock hazard – risk of serious personal injury and/or equipment
interference
If shielded cables are used, make sure the shielded cables do not form a ground loop
via the shield wire and the RJ45 receptacles at either end. Ground loops can cause
excessive noise and interference, but more importantly, create a potential shock
hazard that can result in serious injury.
LEDs
Each port features an LED that indicates its link/activity state.
1
1
Figure 4.2
1
1
Figure 4.3
Pin-Out
The following are the pin-out descriptions for the RJ45 and micro-D connectors:
8
Figure 4.4
18
WARNING
1
Link/Activity LED
LED for RJ45 Ports (9 to 10)
1
Link/Activity LED
LED for Micro-D Ports (9 to
10)
RJ45 Port Pin Configuration
 
 
Pin
1
Name
10/100Base-
1000Base-
TX
TX
1
RX+
BI_DB+
Installation Manual, 01/2021, C79000-G8976-1353-05
Description
Receive
Data+ or Bi-
Directional
RUGGEDCOM RS900GPF