Control and display elements
A Pressure gauge and thermometer
B Rotary selector for DHW tempera-
ture
C Rotary selector for room tempera-
ture
D ON/OFF switch
Heating mode
The set boiler water temperature
adjusted at rotary selector "tr" will
be maintained when a demand is
raised by the room thermostat.
The boiler water temperature will be
maintained at the default frost protec-
tion temperature when there is no
demand.
Function description
E Fault indicator (red)
F ON indicator (green)
G Burner indicator (green)
H Central heating indicator (green)
K DHW heating indicator (green)
The electronic temperature limiter
inside the burner control unit limits the
boiler water temperature to 84 °C.
Flow temperature setting range: 40 to
76 °C.