Viessmann VITOPEND 100-W Installation And Service Instructions Manual page 33

10.5 to 24 kw and 13 to 30 kw. gas fired central heating and combi boilers for open flue operation. natural gas and lpg version
Table of Contents

Advertisement

Control unit diagnostics
8
A
U
tr
ON
fla-
shes
ON
fla-
fla-
shes
shes
ON
fla-
fla-
shes
shes
ON
ON
Extended fault displays
To display detailed fault causes, initially turn rotary selector "rt" fully anti-
clockwise and then fully clockwise.
8
A
U
tr
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
(cont.)
tw
LEDs
Function
flash
fla-
alternat-
Outlet temperature sensor (gas
shes
ing
fired combi boiler) or cylinder
temperature sensor (gas fired
central heating boiler) lead bro-
ken
simulta-
Flue gas monitoring sensor
neously
shorted out
alternat-
Flue gas monitoring sensor lead
ing
broken
Burner control unit fault
To reset the burner switch the
control unit ON/OFF switch first
OFF and then ON again.
tw
LED
Function
flashes
1 time/
The temperature limiter/boil-dry
10 s
protection device has responded.
To reset the burner, turn rotary se-
lector "rt" briefly fully clockwise
"E" and then back to the required
heating water temperature.
2 time/
No flame signal after safety time
10 s
3 time/
The air pressure switch does not
10 s
respond
4 times/
Flame signal present after the
10 s
burner run-on time
5 times/
Flame signal present before burn-
10 s
er start
Troubleshooting
33