Control unit diagnostics
8
A
U
tr
ON
fla-
shes
ON
fla-
fla-
shes
shes
ON
fla-
fla-
shes
shes
ON
ON
Extended fault displays
To display detailed fault causes, initially turn rotary selector "rt" fully anti-
clockwise and then fully clockwise.
8
A
U
tr
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
ON
fla-
shes
(cont.)
tw
LEDs
Function
flash
fla-
alternat-
Outlet temperature sensor (gas
shes
ing
fired combi boiler) or cylinder
temperature sensor (gas fired
central heating boiler) lead bro-
ken
simulta-
Flue gas monitoring sensor
neously
shorted out
alternat-
Flue gas monitoring sensor lead
ing
broken
Burner control unit fault
To reset the burner switch the
control unit ON/OFF switch first
OFF and then ON again.
tw
LED
Function
flashes
1 time/
The temperature limiter/boil-dry
10 s
protection device has responded.
To reset the burner, turn rotary se-
lector "rt" briefly fully clockwise
"E" and then back to the required
heating water temperature.
2 time/
No flame signal after safety time
10 s
3 time/
The air pressure switch does not
10 s
respond
4 times/
Flame signal present after the
10 s
burner run-on time
5 times/
Flame signal present before burn-
10 s
er start
Troubleshooting