General specification - General Welding

WARNING
Explosion hazard!
Batteries emit explosive gases. Always ventilate when using in an enclosed area or when charging.
Keep the battery away from sparks, open flames, and other ignition sources.
Failure to comply could result in death or serious injury.
Use a 7013 or 7011 welding rod or wire that meets the following American Welding Society (AWS) specifications:
ER80S-D2, ER70S-6 or E70C-M6-H4.
NOTICE: ALWAYS disconnect the battery (both terminals) before welding on any part of the machine. Failure to do
so may cause damage to sensitive electrical components.
NOTICE: Locate the welding ground as close as possible to the area to be welded. Do not allow the ground current
to pass through any roller type bearing. Arcing inside the roller bearing can result in severe machine damage.
INTRODUCTION
47667943 24/04/2014
20
W0369A