Engine - Exhaust Gas Recirculation (EGR) - Diesel Particulate Filter (DPF) exhaust treatment
monitor displaying the filter symbol together with "FAIL" and a single acoustic signal. After 2 seconds, the control unit
goes back into the situation at the start of regeneration "START". From this situation, after restoring the necessary
conditions to carry out the operation it is necessary to press the switch (2) on the symbol (B) to restart the regeneration
procedure.
47840679 10/03/2015
10.3 [10.501] / 9