Ash Removal - Viessmann VITOLIG 300 Service Instructions Manual

Pellet boiler
Hide thumbs Also See for VITOLIG 300:
Table of Contents

Advertisement

5. Ash chamber, secondary heating surface
4. Rake ash out.
5. Vacuum the remaining fly ash.

6. Ash removal

1. Open l.h. door.
2. Pull out handle A as far as possi-
ble. The side opening is closed.
3. Release toggle B, push container
slightly to the left and remove.
4. Empty the ash container.
Inspection and maintenance
(cont.)
6. Install clean-out cover C and lock
into place.
7. Insert ash deflector panel A.
5. Check gaskets between ash
container and boiler and the gasket
on the lid of the ash container for
tight fit and condition.
6. Refit the ash container in reverse
order.
7. Check the function of the automatic
ash removal. For this, press the
reset button and the door contact
switch in the combustion chamber
door.