Viessmann VITOLIG 300 Service Instructions Manual page 29

Pellet boiler
Hide thumbs Also See for VITOLIG 300:
Table of Contents

Advertisement

Connection and wiring diagrams
M0c
Induced draught fan motor
M0e
Motor for heating surface clea-
ner
M0f
Motor for ash removal
M2
Motor changeover unit
S1
Combustion chamber door
switch
S2
Shaker limit switch
S3
Capacitive proximity switch
(X14/3
black)
(X14/4
blue)
(X14/6
brown)
S3a
Emergency stop switch
heating system
S4
Flap limit switch
S10
Zero point limit switch
S11
Position limit switch
V0a
Combustion chamber tem-
perature sensor
V0c
Flue gas temperature sensor
V4
Boiler water temperature sen-
sor
XA
Terminal block fuse
XB
Connection plug, supply auger
XD
Terminal block 12 V DC/GND
XG
Connection plug fan and Hall
generator
XN
Connection plug
Power supply 230 VAC
XS
Terminal block: Heating sys-
tem emergency stop switch
and changeover unit motor
X/STB Connection plug, high limit
safety cut-out, supply auger
100 °C
Connection and wiring diagrams
(cont.)
XV
Terminal block 12 V/ext.
Heating demand and change-
over unit limit switch
XZ
Connection plug, suction tur-
bine
X1
Display unit, control unit
X2
Power supply 230 VAC
X3
High limit safety cutout, boiler/
auger
X4
Supply auger
X5
Shaking
X6
Ignition
X7
Heating surface cleaner and
ash removal
X8
Fan motor capacitor
X9
Fan motor
X11
Flue gas temperature sensor
X12
Boiler water temperature sen-
sor and combustion chamber
temperature sensor
X13
Hall signal
X14
Proximity switch, pellet hopper
and shaker limit switch
X15
Combustion chamber door
switch
X16
External heat demand
X17
LON
X18
Analog 0
10 V
X19
Suction turbine
X20
Wand changeover
X21
Zero point/Position limit switch
X22
Flap limit switch
A
Ignition element
B
Hall generator
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl3a

Table of Contents