QK-AS08-N2K Manual
housing, or through the mounting surface under the sensor.
For best performance, mount the AS08-N2K:
As close to the vehicle/boat's centre of gravity as possible.
To accommodate the maximum pitch and roll motions, mount the
sensor as near to horizontal as possible.
Avoid mounting the sensor high above the water line because doing so also increases pitch
and roll acceleration
AS08-N2K does not require a clear view of the sky.
Do NOT install near ferrous metals or anything that can create a magnetic field such as:
magnetized materials, electric motors, electronic equipment, engines, generators, power/ignition
cables, and batteries. If you believe your AS08-N2K isn't accurate please contact your distributor
to re-calibrate your device.

3. Connections

The AS08-N2K sensor has the following connections.
NMEA 0183 port and power. A four-core M12 connector can be connected with the provided 2-
meter cable. This can be connected to the NMEA 0183 listeners and the power supply. The user
can use the configuration tool to setup NMEA 0183 output data type, baud rate and data
frequency.
12V DC via NMEA 0183 port needs to be connected to power up the AS08-N2K
V 1.0
Figure 2 QK-AS08-N2K
Wire
Red
Black
Green
Yellow
4 of 10
Function
12V
GND
NMEA output+
NMEA output –