13
Position of the loading clamp
.14.02
Requirement
1.
The inner claws of the loading clamp must touch the retracted loading table approx.
to 7 mm behind the front edge.
2.
The distance between the front claw edge of the loading clamp and the center of the
needle hole must be 50 mm.
Fig. 13 - 31
●
Adjust the loading clamp (screws
●
Adjust brackets
2
1
3
3
6 - 7 mm
2 (screws 3) in accordance with requirement 2.
1) in accordance with requirement 1.
Adjustment
6
2
3
1
97