4.2 MOTOR CIRCUIT BREAKER PROTECTION

If the thermal protection of the motor is triggered, check the cleanliness
of the slits, the efficiency of the cooling devices and the regular and
friction-free rotation of the motor�
It is recommended to cut off the power supply�

4.3 PROTECTION FUSES

The protection fuses are used to protect the circuit boards of the oven
against overvoltage� These are found in the bottom part of the technical
compartment, near to the safety thermostat rearm button�

4.4 FLAME CONTROL

Caution:
The flame control only functions correctly if the oven electric connection
has been performed respecting the position of the phase and neutral�
Between phases

4.5 SPARE PARTS MANAGEMENT

The parts should be replaced exclusively by an authorized service
centre�
To identify the codes of spare parts, contact a service representative�
Once the parts required have been identified, the after-sales
service will send a written order to the manufacturer, specifying
clearly the model of the device, its serial number, the voltage and
frequency of power supply, and also the code and a description
of the parts concerned.
Only original spare parts must be used for protection of the
health of the user and consumer.
there must be a potential difference of 230V�