3.3 CLEANING THE CONTROL PANEL VENTILATION
FILTER
Cleaning the oven control panel ventilation filter (Fig. 16 - ref. F)
must be done at least once a month,
by hand washing the filter with soap
and water�
To slide the filter out, pull sideways
and outwards with your fingers,
applying force on the relevant hand-
hold (Fig. 16)�
It is good practice to replace the
filter at least once a year or even
more frequently whenever the oven
operates in environments in which
there is a high concentration of flours
or similar substances�
In all cases, the filter must be
replaced when it is consumed or damaged; it must be requested from
the supplier as a spare part�
4. CHECKS THAT CAN ONLY BE PERFORMED BY
AN AUTHORIZED TECHNICIAN
Cut off the power supply before making
any adjustment or intervention.
4.1 RESET THE SAFETY
THERMOSTAT
Loosen the screws that fix the control panel
and open it, making it rotate to the left on its
guides�
Locate the thermostat, positioned in the lower
left side of the technical compartment and
press the red button until a mechanical sound ("click") is heard, which
will confirm the closure of the contacts (Fig. 17)�
The thermostat can be triggered due to mechanical stresses to which
the oven can be subjected during transport�
Continuous intervention of the safety thermostat indicates a malfunction
of the device and makes it essential to investigate the causes�
30
Fig. 16
Fig. 17