GAS Model
Weight
Voltage
Frequency
(Hz)
Absorbed power
(kW)
Minimum power cable
section (mm
)
2
Electric ovens
L1
L2
L3
N
tab. 2
The appliance must be included within an equipotential system whose
efficiency is checked in compliance with the standards in force.
There is a clamp for the connection, located on the frame and marked
with the symbol of Fig. 7, to which a cable with a minimum
10 mm² section must be connected�
For gas ovens, wait until the gas connection to the appliance
has also been completed before re-mounting the side panel of
the oven; instead, for electric ovens, on finishing the electric
connection, re-mount the side panel�

1.6 Connecting the gas (gas ovens only)

NB:
The oven is calibrated originally for operation with the type of gas
specified on placing the order.
The type of gas for which the oven is adjusted is given on the technical
plate positioned on the appliance (Fig.8, ref. A)�
During the inspection, make sure that the factory calibrations on the
burners are appropriate for the specific type of installation, through the
analysis of the gases produced by combustion (CO2 and CO) and the
EMG5...
EMG7...
ECG52
ECG72
ECG52S
ECG72S
120
130
1N 230V
1N 230V
50/60
50/60
0.3
0.6
3 x 1.5
3 x 1.5
Gas ovens
L
N
Between phases
there must be
a difference in
potential of 230 V�
EMG10...
ECG102
ECG102S
160
1N 230V
50/60
0.6
3 x 1.5
tab. 1
Connect the cable to the terminal
block
following
given in tab. 2�
Secure the cable with the cable
gland�
The supply voltage of the appliance
in operation must not deviate from
the nominal voltage by ±10%�
the
instructions
Fig. 7