Content / Innehåll
Installation / Montering ..................................... 2
Cutout dimensions / Håltagningsmått ......................... 2
Suspension / Upphängning ......................................... 3
Air connections / Luftanslutningar ............................... 6
Control equipment / Styrutrustning ............................. 7
Grilles assembly / Gallermontering .............................. 8
Commissioning / Injustering .............................. 9
Maintenance / Skötsel ...................................... 11
Symbols / Symboler
Warning/Caution!
Varning/Observera!
20191126
Art. 942428009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PARAGONc and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Swegon PARAGONc

  • Page 1: Table Of Contents

    PARAGONc Installation – Commissioning – Maintenance 20191126 Art. 942428009 Content / Innehåll Installation / Montering ........2 Symbols / Symboler Cutout dimensions / Håltagningsmått ......2 Warning/Caution! Suspension / Upphängning ......... 3 Varning/Observera! Water connections / Vattenanslutningar ...... 5 Air connections / Luftanslutningar ....... 6 Control equipment / Styrutrustning ......
  • Page 2: Installation / Montering

    PARAGONc Installation / Montering Cutout dimensions / Håltagningsmått 1100 1035 1300 1175 1235 1500 1375 1435 40-65 50-90 Swegon reserves the right to alter specifications. 20191126...
  • Page 3: Suspension / Upphängning

    PARAGONc Suspension / Upphängning D=40-65 C=50-90 20191126 Swegon reserves the right to alter specifications.
  • Page 4 PARAGONc Suspension / Upphängning D=40-65 C=50-90 Swegon reserves the right to alter specifications. 20191126...
  • Page 5: Water Connections / Vattenanslutningar

    Max. recommended test pressure: 2400 kPa Max. permissible inlet flow temperature: 60°C N.B! / OBS! Use support sleeves inside the pipes together with compression ring couplings. Använd stödhylsor i rören tillsammans med klämringskopplingar. 20191126 Swegon reserves the right to alter specifications.
  • Page 6: Air Connections / Luftanslutningar

    PARAGONc Air connections / Luftanslutningar Supply air / Tilluft Extract air / Frånluft A: Min. 70mm A: Min.770mm B: Min. 330mm B: Min. 360mm PARAGONc (R) PARAGONc (R) PARAGONc (L) PARAGONc (L) Swegon reserves the right to alter specifications. 20191126...
  • Page 7: Control Equipment / Styrutrustning

    Control equipment / Styrutrustning CONDUCTOR LUNA W4.1, PS For US and Canada market WARNING: The power feeding to the system shall be a Low Voltage class 2 circuit. W4.1, 2xPS CONDUCTOR / LUNA 20191126 Swegon reserves the right to alter specifications.
  • Page 8: Grilles Assembly / Gallermontering

    PARAGONc Grilles assembly / Gallermontering Swegon reserves the right to alter specifications. 20191126...
  • Page 9: Commissioning / Injustering

    1100 50 - 150 Pa 15,5 - 26,8 2,19 L / M q=15.7 - 31.4 (l/s) k=2,22 q=L/L q = k · √p [l/s] = (q/k) [Pa] L=775, 1100, 1500 L=900, 1300 20191126 Swegon reserves the right to alter specifications.
  • Page 10 50 - 200 Pa 26.3 - 52.5 3,71 L / H 1500 50 - 200 Pa 31.4 - 62.8 4,44 M / H 1500 50 - 200 Pa 38.6 - 77.2 5,46 H / H Swegon reserves the right to alter specifications. 20191126...
  • Page 11: Maintenance / Skötsel

    PARAGONc Maintenance / Skötsel 20191126 Swegon reserves the right to alter specifications.
  • Page 12 PARAGONc Swegon reserves the right to alter specifications. 20191126...