Swegon PARAGON d Installation, Commissioning Maintenance

Advertisement

Quick Links

PARAGON d
Installation - Commissioning - Maintenance
Content
Application area .................................................. 2
General....................................................................... 2
Contents ..................................................................... 2
Protective equipment .................................................. 2
Electrical safety ........................................................... 2
Handling ..................................................................... 2
Installation .................................................................. 2
Disposal ...................................................................... 2
Cleaning ..................................................................... 2
Service/maintenance ................................................... 2
Product warranty ........................................................ 2
Dimensions and weight...................................... 3
Installation .......................................................... 4
Cutout dimensions ...................................................... 4
Suspension ................................................................. 5
Water connection ....................................................... 7
Connecting water ....................................................... 7
Water connection, CCO-valve ..................................... 8
Air connection ............................................................ 9
Connection dimensions air .......................................... 9
Air connections ......................................................... 10
Mounting grills ..........................................................11
Control equipment .................................................... 12
Terminal block .......................................................... 12
PARAGON ................................................................ 12
LUNA ........................................................................ 12
URC1 (VAV) .............................................................. 13
Commissioning .................................................. 14
K-factor setting ......................................................... 14
Maintenance ...................................................... 15
Symbols
Warning/Caution!
06/11/2021
Art. 942428071

Advertisement

Table of Contents
loading

Summary of Contents for Swegon PARAGON d

  • Page 1: Table Of Contents

    PARAGON d Installation – Commissioning – Maintenance 06/11/2021 Art. 942428071 Content Symbols Application area ..........2 General............... 2 Contents ..............2 Warning/Caution! Protective equipment ..........2 Electrical safety ............2 Handling ..............2 Installation ..............2 Disposal ..............2 Cleaning ..............2 Service/maintenance ...........
  • Page 2: Application Area

    (1) The product is repaired, modified or changed, unless such repair, modification or change has been approved by Swegon AB; or (2) the serial number on the product has been made illegible or is missing.
  • Page 3: Dimensions And Weight

    1400 L 23.0 27.6 2.46 1400 R 23.0 27.6 2.47 0.65 1400 L 23.0 27.6 2.46 0.64 1400 R 23.0 27.6 2.47 1400 R 23.0 27.6 2.46 * excl. terminal block: 0,26 kg 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 4: Installation

    8 0 5 / > 2 5 0 5 / 1 3 8 5 ± 7 8 5 / 1 0 8 23,5 569 (+ 0-20) 92,5 92,5 23,5 569 (+ 0-20) 92,5 92,5 Swegon reserves the right to alter specifications. 06/11/2021...
  • Page 5: Suspension

    222,5 146,6 23,5 778,2 222,5 1100 1078,2 222,5 1400 1378,2 222,5 > 2 5 > 1 4 2 2 3 / / 1 1 > 2 8 2 3 > 2 5 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 6 PARAGON d Swegon reserves the right to alter specifications. 06/11/2021...
  • Page 7: Water Connection

    A1 = Cooling water, supply A2 = Cooling water, return A2 = Cooling water, return B1 = Heating water, supply B1 = Heating water, supply B2 = Heating water, return B2 = Heating water, return 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 8: Water Connection, Cco-Valve

    Water connection - CCO-valve. A1 = Cooling water, supply A2 = Cooling water, return B1 = Heating water, supply B2 = Heating water, return C = CCO valve D = Flexible hose Swegon reserves the right to alter specifications. 06/11/2021...
  • Page 9: Air Connection

    PARAGON suite, view from the back (R) PARAGON suite, view from the back (L) Connection dimensions air Variant Length Air connetion (mm) 1 x Ø 125 2 x Ø 125 1: Standard 800, 1100, 1400 2: Suite 1400 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 10: Air Connections

    PARAGON d Air connections Supply air kit Extract air kit A: Min. 70mm A: Min.770mm B: Min. 330mm B: Min. 360mm Swegon reserves the right to alter specifications. 06/11/2021...
  • Page 11: Mounting Grills

    PARAGON d Mounting grills C l i c C li c k ! 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 12: Control Equipment

    24V NC blue LUNA Y20 (G0) Y10 / Y1 (24V AC/DC) Y2 (G0) 0-10 V DC G (24V AC/DC) G0 (0V) 0-10 V DC Temp. sensor Cond. sensor Modbus + Modbus - Swegon reserves the right to alter specifications. 06/11/2021...
  • Page 13: Urc1 (Vav)

    Cable USB-RJ12 Motor Cable adapter 24 V AC / DC Adapter VOC-sensor Pressure sensor 3xRJ12 (Modbus) Sensor module The outputs on the regulator Max 48 VA Max 48 VA Max 48 VA 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 14: Commissioning

     Turn the knob until the marking “D” reaches the required number of degrees. In the example from the table for a PARAGON d, length 1100, ø125, k-factor 2,5, turn the knob to 50°.  Tighten the screw again when the marking is set on the required number of degrees...
  • Page 15: Maintenance

    PARAGON d Maintenance 06/11/2021 Swegon reserves the right to alter specifications.
  • Page 16 PARAGON d C l i c Click! Swegon reserves the right to alter specifications. 06/11/2021...

This manual is also suitable for:

Paragon d 800Paragon d 1100Paragon d 1400