9

Data sheet

9.1

Type

JUDO i-soft TGA 2
Fully automatic water softening system
Order no.: 8203043
9.2

Technical data

– Maximum ambient temperature and wa-
ter temperature 30 °C
– The water to be softened must comply
with the European Drinking Water Di-
rective!
Operating pres-
sure
2 - 7 bar
The rated pressure refers to the pressure
range that the water softening system
meets. The maximum operating pressure is
lower to ensure the optimum function of the
water softening system.
Data sheet
Rated pressure
PN 10
JUDO i-soft TGA 2
Operating weight with full
salt charge
Shipping weight
Rated flow
Flow pressure at min. rated
flow
Pressure loss at rated flow
Temporary max. flow
Pipe connection
Rated capacity
Capacity per kg regenerat-
ing salt
Volume of the salt reservoir 50 kg
Volume of the exchanger
resin
Water consumption per re-
generation
Electrical connection
Power consumption:
Operation
Regeneration
Adjustment range
of desired
water hardness
Max. raw water hardness
Further information is available in
chapter 9.3 "Graphs".
approx.
75 kg
approx.
28 kg
1.8 m³/h
2 bar
1 bar
3.5 m³/h
1"
1.2 mol
6 mol
6 l
approx. 25 l
230 V/
50 Hz
3 W
max. 20 W
min.
1 °e
max.
half value of
the
untreated
drinking
water
hardness
+ 2 °e