Main Functions
1.3

Airflow Direction Control

Power-Airflow
The large flap sends a large volume of air downward to the floor and provides an optimum control in
Dual Flaps
cooling, dry and heating operation.
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
Heating
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
Louvers
comfortable air distribution.
Auto-Swing
The following tables explain the auto-swing process for cooling, dry, heating and fan:
3-D Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The vertical blades (louvers) move from the right to the left.
(2) The horizontal blades (flaps) move downward.
(3) The vertical blades (louvers) move from the left to the right.
(4) The horizontal blades (flaps) move upward.
26
Flap (up and down)
Cooling/Dry
Heating
R4003783
Fan
R4003784
R4003785
(1)
(2)
(3)
SiUS042113E
Louver
(right and left)
R4003764
(4)
(R19554)