Field Settings
1
Overview of the Settings
Setting items
Brightness
1
Filter cleaning setting
2
Suspend
3
Dry keep
4
Preheating control
5
Room temperature
adjustment (cooling)
6
Room temperature
adjustment (heating)
7
Airflow setting when
8
thermostat off during
cooling operation
Wireless/HA priority setting
9
during automatic operation
Auto-restart
10
Warmer airflow setting
12
* 09/12 class: N/A
156
Field settings mode
Room temperature adjustment settings may be applied.
When changing the settings, make sure the button was correctly pressed by listening for
the beep sound. (The beep can be heard even if the button is pressed within a setting
which is unavailable. In this case, the setting will be invalid.)
Press the
buttons to change the setting items and the setting values.
Setting items
Factory
Setting options
setting
0: OFF
1: Dark
N/A
2: Bright
0: Short
N/A
1: Long
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: Low 2 (–2°C)
1: Low 1 (–1°C)
2: Standard (0°C)
3: High 1 (+1°C)
4: High 2 (+2°C)
0: Low 2 (–2°C)
1: Low 1 (–1°C)
2: Standard (0°C)
3: High 1 (+1°C)
4: High 2 (+2°C)
0: Keep
1: Soft breeze
N/A
0: Wireless
1: HA
N/A
0: OFF
1: ON
0: OFF
1: ON
Setting values
Brightness of indoor unit LED lamp
Determines the duration/time to display Filter cleaning sign.
Activation/Deactivation of Standby electricity saving (suspend
function)
0: Power will still be supplied to the outdoor unit PCB after the unit
1
operation stopped.
1: Three minutes after the unit operation stops, the power supply to
the outdoor unit PCB is shut off.
Stops the airflow of indoor unit when the thermostat is OFF to
prevent increase of room humidity.
0: When thermostat is OFF, the fan rotor will still be OPERATING,
0
hence there is airflow.
1: When thermostat is OFF, the fan rotor will be STOPPED, hence
there is no airflow.
Activation/Deactivation of compressor preheating
0*
0: Deactivation of compressor preheating
1: Activation of compressor preheating
Adjustment of indoor temperature thermistor in cooling operation
Used for adjustment of room temperature control.
2
Adjustment of indoor temperature thermistor in heating operation.
Used for adjustment of room temperature control.
2
Airflow setting when indoor unit thermostat is off.
0: Same airflow as "thermostat on"
1: Lowered to LL tap
Determination of priority control method when HA system is used.
0: Wireless remote controller can be used.
1: Temperature setting from wireless remote controller is disabled.
This setting decides the operation of the unit when the power supply
resumed after a power supply shutdown (i.e. power failure).
0: When the power supply resumes, the unit remains in stopped
1
operation.
1: When the power supply resumes, the unit resumes the operation
before the shutdown of power supply.
This setting makes the discharge airflow temperature warmer.
0
SiUS042113E