Installation manual e-MatriX heat Dear user Product: electric fire Opti-myst Model: e-MatriX heat 800/500 I,II,III Congratulations on your purchase of a Faber fire! A e-MatriX heat 800/650 I,II,III quality product from which you will experience warmth and atmosphere for many years. We ...
Page 7
Installation manual e-MatriX heat 800/500-650 I,II,III Placing the fire Water connection This appliance is equipped with the following For a proper functioning of the fire, always ensure (overflow) protections: that the fire is levelled. Electromechanical valve in the Control box that is controlled by sensors in the Floor standing water tank.
Installation manual e-MatriX heat 800/500-650 I,II,III Side glass Maintenance For cleaning only it’s not necessary to remove the side glass. Maintenance frequency First remove the front glass see chapter 5. Cleaning water sump, air filter and Place a suction cup and remove the side replacing transducers.
Installation manual e-MatriX heat 800/500-650 I,II,III Cleaning air filter Replacing in-line filter Gently slide the air filter upwards out of Turn off the water supply. its plastic holder, see fig. 8.0. Close the ball valves. Gently rinse with water in the sink and dry Replace the in-line filter.
Page 10
Installation manual e-MatriX heat 11 Troubleshooting and fault codes remote control Code Symptom Cause Action The flame effect will not No power supply. Check if power supply is connected to wall start. socket correctly and the mains switch of the Control box is in the ON (I) position.