Download Print this page

Faber e-MatriX heat 800/500 I Installation Manual

Hide thumbs Also See for e-MatriX heat 800/500 I:

Advertisement

Quick Links

Installation manual
e-MatriX heat 800/500 I,II,III
e-MatriX heat 800/650 I,II,III
ENG
40011796-1944

Advertisement

loading
Need help?

Need help?

Do you have a question about the e-MatriX heat 800/500 I and is the answer not in the manual?

Questions and answers

Summary of Contents for Faber e-MatriX heat 800/500 I

  • Page 1 Installation manual e-MatriX heat 800/500 I,II,III e-MatriX heat 800/650 I,II,III 40011796-1944...
  • Page 2 Installation manual e-MatriX heat 800/500-650 I,II,III 2.0a 2.0b 1 < < < <...
  • Page 3 Installation manual e-MatriX heat 800/500-650 I,II,III 2.0c 2.1a 2.1b 2.1c 2 < < < <...
  • Page 4 Installation manual e-MatriX heat 800/500-650 I,II,III 3 < < < <...
  • Page 5 Installation manual e-MatriX heat 800/500-650 I,II,III 4 < < < <...
  • Page 6: Installation Requirements

    Installation manual e-MatriX heat Dear user Product: electric fire Opti-myst Model: e-MatriX heat 800/500 I,II,III Congratulations on your purchase of a Faber fire! A e-MatriX heat 800/650 I,II,III quality product from which you will experience warmth and atmosphere for many years. We ...
  • Page 7 Installation manual e-MatriX heat 800/500-650 I,II,III Placing the fire Water connection This appliance is equipped with the following For a proper functioning of the fire, always ensure (overflow) protections: that the fire is levelled. Electromechanical valve in the Control box that is controlled by sensors in the Floor standing water tank.
  • Page 8: Maintenance

    Installation manual e-MatriX heat 800/500-650 I,II,III Side glass Maintenance For cleaning only it’s not necessary to remove the side glass. Maintenance frequency  First remove the front glass see chapter 5.  Cleaning water sump, air filter and  Place a suction cup and remove the side replacing transducers.
  • Page 9: Technical Data

    Installation manual e-MatriX heat 800/500-650 I,II,III Cleaning air filter Replacing in-line filter Gently slide the air filter upwards out of Turn off the water supply. its plastic holder, see fig. 8.0. Close the ball valves. Gently rinse with water in the sink and dry Replace the in-line filter.
  • Page 10 Installation manual e-MatriX heat 11 Troubleshooting and fault codes remote control Code Symptom Cause Action The flame effect will not No power supply. Check if power supply is connected to wall start. socket correctly and the mains switch of the Control box is in the ON (I) position.
  • Page 11 Installation manual e-MatriX heat 800/500-650 I,II,III 12 Dimensional drawings 12.1 e-MatriX heat 800/500-650 I 10 < < < <...
  • Page 12 Installation manual e-MatriX heat 800/500-650 I,II,III 12.2 e-MatriX heat 800/500-650 IIL 11 < < < <...
  • Page 13 Installation manual e-MatriX heat 800/500-650 I,II,III 12.3 e-MatriX heat 800/500-650 IIR 12 < < < <...
  • Page 14 Installation manual e-MatriX heat 800/500-650 I,II,III 12.4 e-MatriX heat 800/500-650 III 13 < < < <...
  • Page 15 Installation manual e-MatriX heat 800/500-650 I,II,III 12.5 Control box 14 < < < <...
  • Page 16 Installation manual e-MatriX heat 800/500-650 I,II,III 12.6 Wall brackets e-MatriX 800/500 I,II, III heat (Article number A9325196) e-MatriX 800/650 I, II, III heat (Article number A9324596) 15 < < < <...
  • Page 17 Installation manual e-MatriX heat 800/500-650 I,II,III 12.7 Remote access door (Article number A9299463) 16 < < < <...
  • Page 18 Installation manual e-MatriX heat 800/500-650 I,II,III 17 < < < <...
  • Page 19 Installation manual e-MatriX heat 800/500-650 I,II,III 18 < < < <...
  • Page 20 www.faberfires.com contact@faberfires.com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen...