線跡狀態調整
1. 過線器 (A) 的位置是從固定螺絲 (B) 的中心
算起約 11.5mm 前後。( 圖 43)
2. 鬆線器與過線器的位置和調整:
過線器 (C) 在長直孔約中心處鎖緊固定螺絲
(D),如果把過線器 (C) 往左調,線較鬆弛 ;
如往右調,則線較緊繃。鬆線器 (E) 通過過
線器 (C) 的中心位置後,鎖緊螺絲 (F)。( 圖
44)
A D J U S T I N G T H E S T I T C H
FORMATION
圖 43/Fig 43
1.The position of the needle thread eyelet (A)
should be adjusted about approx. 11.5mm
from the center of the screw (B). (Fig 43)
2.Position of the looper thread take-up eyelet
The looper thread eyelet (C) is to be fastened
by the screw (D) at the center of its long-
hole.If turn the looper thread eyelet (C) to the
left,line is relaxation.If turn the looper thread
eyelet (C) to the right,line is tight.
After the looper take-up (E) passes the
center position of the looper thread eyelet
(C), tighten the screw (F). (Fig 44)
Introduction
圖 44/Fig 44