Checks After Starting Engine; Cooling Water - Yamaha F115A Owner's Manual

Hide thumbs Also See for F115A:
Table of Contents

Advertisement

TIP:
Dual engine users: When the main switch is
turned on, the buzzer operates for a few sec-
onds then stops automatically. The buzzer
also operates if one of the engines stalls.
5.
Turn the main switch to "
and hold it for a maximum of 5 seconds.
ON
START
6.
Immediately after the engine starts, re-
lease the main switch to return it to "
(on). NOTICE: Never turn the main
switch to "
gine is running. Do not keep the start-
er motor turning for more than 5
seconds. If the starter motor is turned
continuously for more than 5 seconds,
the battery will be quickly discharged,
thus making it impossible to start the
engine. The starter can also be dam-
aged. If the engine will not start after 5
" (start),
ZMU04590
" (start) while the en-
seconds of cranking, return the main
switch to "
then crank the engine again.
EMU36511

Checks after starting engine

EMU36524

Cooling water

Check for a steady flow of water from the
cooling water pilot hole. A continuous flow of
water from the pilot hole indicates that the
water pump is pumping water through the
cooling water passages. If the cooling water
passages are frozen, it may take a while for
water to start flowing out of the pilot hole.
ECM01811
NOTICE
If water is not flowing out of the pilot hole
at all times while the engine is running,
overheating and serious damage could
occur. Stop the engine and check whether
the cooling water inlet on the lower case
or the cooling water pilot hole is blocked.
Consult your Yamaha dealer if the prob-
lem cannot be located and corrected.
"
Operation
" (on), wait 10 seconds,
[ECM00193]
68

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fl115aF115a1Fl115a1F150aFl150aF150a2 ... Show all

Table of Contents