9. Universal Washroom Mode

Normally is unlocked
Install the door operator for required application based on installation instructions
Adjust parameters for basic setup
Follow the universal washroom wiring diagram to connect all the devices to proper terminals
Once the devices are wired and door operator is programmed for basic setup, access the advanced settings to
change operating mode of the controller

9.1 Parameters

Latch time: Change from 2 to 0
Control mode: Change from 1 to 2
Once the door is closed the display will say door closed (unoccupied)

10. Access control mode

1. Install the door operator following instructions
2. Adjust parameters for basic setup
3. Follow to access control wiring diagram
4. Signal from access control panel needs to be dry to connect device and signal from access control panel to proper
terminals.
5. Once devices are wired and the door operator is programmed for basic setup, access advanced settings to change
operating mode of controller.
10.1 Parameters
✓ Control mode: Change from 1 to 3
Door Closed
[Unoccupied]
Fig 9.1.1