Pull Arm Application - Omega OAL-100 Installation Instructions Manual

Hide thumbs Also See for OAL-100:
Table of Contents

Advertisement

✓ Push the door slightly to release the locked rod from gearbox, if loaded using power then remove jumper wire
from terminals com and ACT 2.
✓ The door should work as it has a manual closer.
✓ Attach the PH3 screw with safety washer on bottom of spindle.
✓ Door operator is now installed and ready for programming.

7.4.2 Pull arm application

First of all, the operator needs to reach the hard stop itself (by adding a jumper wire like Fig 7.4.1.1) or manually with the
pull arm. In the next step push the rod into gearbox (same as Fig 7.4.1.4) to stop it, then open the door to your desired
fully open position and attach the pull arm to the spindle (Fig 7.4.2.1). In the last step, take out the rod and release the arm
to reach the fully close position.
Fig 7.4.1.4
Fig 7.4.1.5
OMEGA AUTOMATICS 2020 v3.0.2