Introduction
The Control4® Configurable Keypad is intended for use in a Control4 system. It
installs in a standard wallbox using typical wiring standards and communicates to
the Control4 system using a wireless connection.
Box Contents
Configurable Keypad
Keycap Button Kit
Wire Nuts
Warranty Card
Configurable Keypad Installation Guide (this document)
Keypad Button Installation Guide
Specifications
The specifications are described below.
Model Number
Power Requirements
Power Consumption
Operational Temperature
Humidity
Storage
Control Communications
Wallbox Volume
Weight
Shipping Weight
Configurable
Keypad
Installation Guide
C4-KC120277-xx
120-277 VAC +/-10% 50/60 Hz
36-48VDC
This device requires a neutral AC
connection.
120V: 350mW
277V: 540mW
36VDC: 430mW
Environmental
32˚ F - 104˚ F (0˚ C - 40˚ C)
5% to 95% non-condensing
-4˚ F - 158˚ F (-20˚ C - 70˚ C)
Miscellaneous
ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
4.75 cubic inches
0.12 lb. (0.05 kg)
0.18 lb. (0.08 kg)
Warnings and Considerations
WARNING!
Turn OFF electrical power before installing or servicing this
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
ATTENTION!
Coupez l'alimentation électrique avant d'installer ou de
réparer ce produit. Une mauvaise installation ou utilisation peut entraîner
des blessures graves, décès ou perte / dommages à la propriété.
WARNING!
This device must be protected by a circuit breaker (20A max).
ATTENTION!
Cet appareil doit être protégé par un disjoncteur (20A max.)
WARNING!
Ground this device in accordance with the National Electric
Code (NEC) requirements. DO NOT rely solely upon the yoke plate's
contact with a metal wallbox for adequate grounding. Use the device's
ground wire to make a secure connection to the safety ground of the
electrical system.
Cet appareil doit être en conformité avec le Code national de
ATTENTION!
l'électricité (NEC). Ne comptez pas uniquement au contact de la plaque
avant avec un boîtier mural métallique pour la mise à la terre adéquate.
Utilisez cet appareil à la terre de l'appareil pour établir une connexion
sécurisée au système électrique.
IMPORTANT!
This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
IMPORTANT!
If you are unsure about any part of these instructions,
consult a qualified electrician.
IMPORTANT!
Use this device only with copper or copper-clad wire. Do
not use aluminum wiring. This product has not been approved for use with
aluminum wiring.
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See "Troubleshooting."
IMPORTANT!
Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT!
This is an electronic device with intricate components.
Handle and install with care!
Installation Instructions
1
Ensure that the location and intended use meet the following criteria:
When replacing a traditional 3-way switch, refer to the "Two-Location"
sample wiring configurations provided in the appropriate load control device
installation guide.
Install in accordance with all national and local electrical codes.
The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout of the
home; (3) walls separating devices; and (4) electrical equipment located near
devices.
2
Turn off the local electrical power by either switching off the circuit breaker or
removing the fuse from the fuse box. To ensure the wires do NOT have power
running to them, use an inductive voltage detector.
NOTE:
The wallbox wiring shown in this document is an example. Your
wire colors and functions may differ. If you are not sure which wires are
the Hot, Neutral, and Ground wires, have a trained electrician do the
installation.

Advertisement

loading

Summary of Contents for Control 4 C4-KC120277 Series

  • Page 1 ™ Warnings and Considerations Configurable WARNING! Turn OFF electrical power before installing or servicing this product. Improper use or installation can cause SERIOUS INJURY, DEATH Keypad or LOSS/DAMAGE OF PROPERTY. Installation Guide ATTENTION! Coupez l’alimentation électrique avant d’installer ou de réparer ce produit.
  • Page 2 Prepare each wire. Wire insulation should be stripped back 5/8 of an inch Install the Top Actuator Bar, Bottom Sensor Bar, and buttons following the instructions in the “Button Installation” section below. from the wire end (see Figure 1). Install the Control4 Faceplate following the instructions in the Faceplate Figure 1.
  • Page 3 ™ Warranty For complete warranty information, including details on consumer legal rights as well as warranty exclusions, review the Warranty card or visit www.control4.com/ warranty. About this Document Part Number: 200-00309, Rev. D 8/07/2013...
  • Page 4 Copyright ©2013 Control4. . All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners Pricing and specifications are subject to change without notice...

This manual is also suitable for:

C4-kc120277