Rohs; Emc And Environmental Type Tests - Siemens RUGGEDCOM RS8000H Installation Manual

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RS8000H:
Table of Contents

Advertisement

6.1.5

RoHS

This device is declared by Siemens Canada Ltd. to meet the requirements of the
following RoHS (Restriction of Hazardous Substances) directives for the restricted use
of certain hazardous substances in electrical and electronic equipment:
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS8000H has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
RUGGEDCOM RS8000H
Installation Manual, 12/2021, C79000-G8976-1022-06
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
Description
Enclosure
Contact
Enclosure Air
Enclosure
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Signal ports
DC Power
ports
AC Power
ports
Signal ports
DC Power
ports
AC Power
ports
Earth
ground ports
Enclosure
ports
Certification
6.1.5 RoHS
https://
Test Levels
±8 kV
±15 kV
20 V/m
±4 kV @ 2.5 kHz
±4 kV
±4 kV
±4 kV
±4 kV line-to-earth,
±2 kV line-to-line
±2 kV line-to-earth,
±1 kV line-to-line
±4 kV line-to-earth,
±2 kV line-to-line
10 V
10 V
10 V
10 V
40 A/m continuous,
1000 A/m for 1 s
Severity
Levels
4
4
x
x
4
4
4
4
3
4
3
3
3
3
 
27

Advertisement

Table of Contents
loading

Table of Contents