Step 2 - Ventilation - Zenith HydroTap G5 Installation Instructions Manual

Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

Step 2 – Ventilation
IMPORTANT: Allow a minimum clearance envelope of 50mm either
!
side, and 200mm above the Command Centre. Proper air circulation
must be provided for the system to operate correctly. The top and front of
the Command Centre must remain accessible for servicing.
Fit the silicone door buffers to the inside edge of the
2.1
cupboard door to provide an air space.
Install vent tray kit
2.2
(supplied)
Install the vent tray in
the cupboard where
the Command Centre
is located. Refer to
instructions supplied with
Clearance
Envelope
the vent tray.
Inlet Vent
100 min.
If vent tray is unable to be installed:
2.3
280
Additional ventilation will be required. Options
include vent grilles and a dual exhaust fan kit.
Contact your local service centre for more details.
100
150
Sink shown
only
Installation instructions
Outlet Vent
70 min.
200
807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct
See Detail B
A
Inlet vent
options
IEC Flex & Plug
240 - 230V,
50Hz GPO
Attach side duct
(supplied)
Insert into the slots in
the side of the HydroTap
Command Centre. Fasten
with a screw.
DETAIL: Vent Tray air outlet
cut-out in cabinet floor
A
250
300
See Detail A
See Detail C
100mm min
between cut-outs
Outlet vent
450mm cut-out
Connector
with Strainer
(Feeds Base Unit)
450
Mains cold water
(18")
isolation valve
(not supplied)
Hot water from
domestic heater
350
93156 Dual Exhaust Fan Kit
4 min
Buffe
Air S
400
09