Water Tank with fresh water, put it back onto the unit and switch on the
unit again.
Note: turn off the unit before taking off the tank. You need to turn on the
unit again when placing the tank back to the unit.
Althrough the unit shuts off its motor and its transdusor automatically
when water runs off and the «No water» LED light turns on, in order to
avoid unexpected damages, we recommend you to switch off the unit by
pressing the On/Off Button as soon as the «No water« Light is on.
Filter Cartridge and Water Hardness
• The life-span of the cartridge is dependent on the hardness of the water.
This can be tested using the test strip supplied (The test strip is adhered
to the reverse side of this instruction manual).
• Dip the test strip into the water for one second.
• After approx. one minute, the result can be seen on the measuring strip.
Some of the green areas will change their colour to pink. The number of
pink areas corresponds to the hardness of the water.
Example: If there are three pink areas, the water has a hardness of «3».
Number of
Water
Hardness
pink areas
hardness
(°dH)
0/1
soft
ab 4°dH
2
medium
ab 7°dH
3
Slightly hard
ab 14°dH
4
Very hard
ab 21°dH
A simple test can be carried out to determine whether the cartridge is func-
tioning correctly: hold a small mirror in the mist coming out from the unit for
a few seconds. If a white deposit has been left on the mirror (a sign of lime
scale), the cartridge needs to be replaced.
Ionic Silver Cube (ISC™)(optional)
Before attaching the water tank, insert the «Silver Cube» in the base in the
position indicated.
The ISC™ with its patented technology prevents the growth of bacteria and
germs. It can be used for a maximum of one season, and must be replaced at
the start of the next heating season (i.e. when the weather becomes cold).
Despite using the Ionic Silver Cube (ISC™) or the Antimicrobial Stick, you
should replace the water on a daily basis

USEFUL INFORMATION

Information on how an ultrasonic vaporiser works
How does the ultrasonic vaporiser work? An ultrasonic membrane in the in-
terior of the device causes the water to oscillate, causing very fine droplets
of water to be «catapulted off» from the water surface. These droplets mix
with the air in the spray chamber and are then blown into the room through
Cartridge needs replacing after
days/litres (for 3 litres per day)
approx. 120 days approx. 360 litres
approx. 60 days approx. 180 litres
approx. 40 days approx .120 litres
approx. 20 days approx. 60 litres
a ventilator as a visible spray. This fine spray evaporates in the warm air in
the room, moistening the air that people breathe.
White dust:
The ultrasonic vaporiser's method of action causes all substances contained
in the water to be sprayed, including calcium carbonate (a cause of limes-
cale) and minerals. In order to prevent this as far possible, the water is fed
through the filter cartridge before being sprayed. The cartridge retains a
large percentage of the substances contained in the water. Tap water varies
greatly from region to region in terms of its calcium and mineral content.
Some minerals cannot be sufficiently filtered by the descaling resin used. In
this case, a white, dust-like deposit is left in the room, which is first visible
on electro-statically charged surfaces (such as TV sets). This deposit also
occurs when the filter cartridge needs replacing (see the chapter on «Filter
Cartridge and Water Hardness»).
Tips for water
Do not use water that has been subject to salt-based softening in a de-
scaling system. These systems replace the calcium with salt, which then
settles in the room as a white deposit.
Clean water must always be used to ensure that the air remains hygienic
to breathe. The device, and the water tank in particular, must always be
hygienically clean.
Recommendation: always use the Ionic Silver Cube (ISC™), as this reduces
the formation of germs in the water.

CARE AND CLEANING

• Switch off the device and unplug the power cable from the socket before
all maintenance work and after each use.
• Never submerge the device in water (this can result in short-circuiting).
To clean the device, simply wipe it with a damp cloth and then dry it tho-
roughly. Always ensure the power cable has been unplugged beforehand.
• Descale the humidifier as appropriate for the hardness of the water, but
at least once a week: First remove the water tank (the upper section) and
clean it with a brush. Descale the device with a standard descaler and
then rinse it thoroughly. Reassemble the device completely before use.
• Thoroughly rinse out the water tank on a regular basis.
• Replace Filter Cartridge (4) every 1-2 months as appropriate for the hard-
ness of the water.
TROUBLE-SHOOTING
«No Water» alarm light does not switch off after tank has been filled with
water:
The device switches off automatically if there is not enough water. The «No
Water» Light switches on (in red color) to warn you for the refill. To restart
the generation of mist, the device must first be switched off and then swit-
ched back on again (this resets the device). This is a protective function for
the ultrasonic vaporiser.