  • Page 1 Original Instructions Original Instructions CAUTION. Read instructions before using the machine. CAUTION. Read instructions before using the machine. HZ370 / HZD570 (H Class)
  • Page 2 Kit AS48 Air Diffuser Hose...
  • Page 3 Using your machine Start Netzschalter Démarrage Start Ligar Avvio Encender Otwarty Moving your Machine...
  • Page 4 Changing the bag Remove the cloth filter (A) from the drum. Remove the HEPAFLO dust bag and seal the dust bag hole. Place the dust bag inside an impervious plastic bag and seal the bag. Dispose of the plastic bag, depending on contamination, in an appropriate manner.
  • Page 5 Cleaning your TriTex Filter...
  • Page 6 Replacing the Cartridge Filter 901649 H13 Filter Cartridge...
  • Page 7 Low Flow Warning Light Lo - Flow Indicator. This appliance is fitted with a low flow indicator to show that air flow has reduced. In the event of the indicator light flashing, check the following:- Cause Solution Dust caps still fitted Remove the caps.
  • Page 8 Changing / Replacing Cable...
  • Page 9: Rating Label

    Sign NOTE: A risk assessment should be conducted to determine which PPE should be worn. Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the Numatic Technical helpline +44 (0)1460 269268 Safety Critical Components Mains leads: H05VV-F 10 m x 3 Core x 1.0mm²...
  • Page 10 Replace any worn or damaged parts immediately. • Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be replaced by a qualified person using the correct Numatic original part. • Change dust bag frequently.
  • Page 11: Important User Information

    Only use the dust collection bag (NVM-2BH) once. This machine must only be repaired by suitably trained and authorised personnel. Only use genuine Numatic International Ltd spare parts, for repairs. This machine must not be installed as a fixed extraction system or run unattended.
  • Page 12: Maintenance

    Regularly examine the supply cord for damage, such as cracking or ageing. If damage is found, replace the cord before further use. All parts of this vacuum are safety critical only replace with the genuine Numatic spare parts. For user servicing, the machine must be dismantled, cleaned and serviced, as far as is reasonably practicable, without causing risk to maintenance staff and others.
  • Page 13: Replacement Parts

    Data 68 dB(A) HZ 370-2 15 L 11.0 kg 355 mm x 355 mm x 570 mm 0.5 dB 26.8m Class I 72 dB(A) HZD 570-2 23 L 20.0 kg 415 mm x 415 mm x 746 mm 0.5 dB Weight Sound Pressure (LpA) Drum Size...
  • Page 14 Schematic Diagram HZ Model WD-0235 (A04) HZD Model WD-0229 (A08)
  • Page 15: Warranty

    Numatic   I nternational   L imited   w arrant   t o   t he   o riginal   p urchaser   t hat   i ts   p roducts   a re   f ree   o f  ...
  • Page 16 Affix Label Here Distributed by Numatic International Limited. Chard, Somerset TA20 2GB ENGLAND Tel: 01460 68600 www.numatic.co.uk Specification subject to change without prior notice www.numatic.co.uk © Numatic International Limited 914147 10/21 (A02)