American Standard PFWF071A93ABA Installation Manual page 8

Oil fired water boiler with three pass cast iron heat exchanger
Table of Contents

Advertisement

Table 1 - General Specifications (Continued)
1
Model
Input BTU/hr
DOE BTU/hr
I=B=R Net BTU/hr
Efficiency - AFUE
Electrical Power Supply
Minimum Circuit Ampacity - amps
Maximum Overcurrent Protection
Nominal Flue Outlet Dia. - inches (tapered)
No. of Heat Exchanger Passes
No. of Sections
Water Content - Gallons
Supply Water Connection - NPT female (in casting)
Return Water Connection - NPT female (in casting)
Maximm Working Pressure - PSIG
Combustion Chamber Pressre Drop - in w.c.
Combustion Chamber Volume - Cubic Feet
0
Water Pressure Drop 10
Td - Ft Head
0
Water Pressure Drop 20
Td - Ft Head
0
Water Pressure Drop 30
Td - Ft Head
Riello Non Direct Vent (40 Series)
Riello Direct Vent (40 Series)
Crated Dimensions - inches (H x W x D)
Ship Weight (Lbs) / Net (Lbs)
1
Model
Input BTU/hr
DOE Output BTU/hr
I=B=R Net BTU/hr
Efficiency - AFUE
Electrical Power Supply
Minimum Circuit Ampacity - amps
Maximum Overcurrent Protection
Nominal Flue Outlet Dia. - inches (tapered)
No. of Heat Exchanger Passes
No. of Sections
Water Content - Gallons
Supply Water Connection - NPT female (in casting)
Return Water Connection - NPT female (in casting)
Maximm Working Pressure - PSIG
Combustion Chamber Pressre Drop - in w.c.
Combustion Chamber Volume - Cubic Feet
0
Water Pressure Drop 10
Td - Ft Head
0
Water Pressure Drop 20
Td - Ft Head
0
Water Pressure Drop 30
Td - Ft Head
Riello Non Direct Vent (40 Series)
Riello Direct Vent (40 Series)
Crated Dimensions - inches (H x W x D)
Ship Weight (Lbs) / Net (Lbs)
Notes
1. * May be "A" or "T"
2. Riello burner purchased separately as an accessory. Ships pre-assembled. Burner cord pre-wired with 7 pin plug that
connects to boiler
3. BAYRAF05 and BAYRBF05 ship with a factory installed nozzle for use with *PFWF132A. Two additional nozzles are
included which require field installation; one each for use with *PFWF164A and *PFWF201A
4. BAYRAF10 ships with a factory installed nozzle for use with *PFWF242A. An additional nozzle, which requires field
installation, is included for use with *PFWF286A
5. Boiler is shipped with 30 psi ASME Pressure Relief Valve
6. Boiler ships with straight nipples. Nipples are 1-1/4" NPT male x 1-1/2" NPT male and 1-1/4"NPT male x 1-1/2" NPT male x 3/4" NPT female.
18-CG03D1-4
8
6
6
5
2,3
2,3
6
6
5
2,4
2,4
*PFWF164A96ABA
164,000
143,000
125,000
86.1
115 volts / 1 phase / 60 hertz
less than 12.0
15
5
3
6
6.7
1-1/4"
1-1/4"
60.0
0.12
1.62
1.1
0.3
0.2
BAYRAF05ABURNA
BAYRBF05ABURNA
40-3/16 x 36-5/8 x 23-5/8
497 / 454
*PFWF242A98ABA
242,000
212,000
185,000
86.5
115 volts / 1 phase / 60 hertz
less than 12.0
5
3
8
9.1
1-1/4"
1-1/4"
60.0
0.16
2.12
2.3
0.6
0.3
BAYRAF10ABURNA
-
40-3/16 x 44-1/2 x 23-5/8
632 / 582
*PFWF201A97ABA
201,000
176,000
153,000
86.3
5
3
7
7.9
1-1/4"
1-1/4"
60.0
0.14
1.87
1.6
0.5
0.2
BAYRAF05ABURNA
BAYRBF05ABURNA
40-3/16 x 40-9/16 x 23-5/8
565 / 518
*PFWF286A99ABA
286,000
252,000
219,000
86.7
15
5
3
9
10.3
1-1/4"
1-1/4"
60.0
0.20
2.37
3.2
0.9
0.4
BAYRAF10ABURNA
-
40-3/16 x 48-7/16 x 23-5/8
698 / 646