American Standard PFWF071A93ABA Installation Manual page 3

Oil fired water boiler with three pass cast iron heat exchanger
Table of Contents

Advertisement

▲ ▲
WARNING
!
SAFETY HAZARD
THESE BOILERS ARE NOT APPROVED OR
INTENDED FOR INSTALLATION IN MANU-
FACTURED (MOBILE) HOUSING, TRAILERS,
OR RECREATIONAL VEHICLES. FAILURE
TO FOLLOW THIS WARNING COULD RESULT
IN SERIOUS INJURY, DEATH, OR PROPERTY
DAMAGE.
▲ ▲
WARNING
!
WATER DAMAGE HAZARD
DO NOT USE THIS UNIT IF ANY PART HAS
BEEN UNDER WATER. IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN TO INS-
PECT THE BOILER AND TO REPLACE ANY
PART OF THE CONTROL SYSTEM AND ANY GAS
CONTROL WHICH HAS BEEN UNDER WATER.
FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN SERIOUS INJURY, DEATH, OR PRO-
PERTY DAMAGE.
!
BURN HAZARD
BEFORE OPENING THE BOILER DOOR,
DISCONNECT BURNER CORD AT THE PLUG.
FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN SERIOUS INJURY, DEATH, OR PRO-
PERTY DAMAGE.PR0PERTY DAMAGE.
▲ ▲
WARNING
!
If the information in this manual is not followed exactly,
a fire or explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier,
call the fire department.
— DO NOT RELY ON SMELL ALONE TO DETECT
LEAKS. DUE TO VARIOUS FACTORS, YOU MAY
NOT BE ABLE TO SMELL FUEL GASES.
• U.L. recognized fuel gas and CO detectors are
recommended in all applications, and their
installation should be in accordance with the
manufacturer's recommendations and/or local
laws, rules, regulations, or customs.
— Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WARNING
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each
appliance connected to the venting system being
placed into operation could result in carbon monoxide
poisoning or death.
The following steps shall be followed for each appliance
connected to the venting system being placed into
operation, while all other appliances connected to the
venting system are not in operation:
1. Seal any unused openings in the venting system.
2. Inspect the venting system for proper size and
horizontal pitch, as required in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the CAN/CGA B149
Installation Codes and these instructions. Determine
that there is no blockage or restriction, leakage,
corrosion and other deficiencies which could cause an
unsafe condition.
3. As far as practical, close all building doors and
windows and all doors between the space in which the
appliance(s) connected to the venting system are
located and other spaces of the building.
4. Close fireplace dampers.
5. Turn on clothes dryers and any appliance not
connected to the venting system. Turn on any exhaust
fans, such as range hoods and bathroom exhausts, so
they are operating at maximum speed. Do not operate
a summer exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the thermostat
so appliance is operating continuously.
7. If improper venting is observed during any of the above
tests, the venting system must be corrected in
accordance with the National Fuel Gas Code,
ANSI Z221.1/NFPA 54 and/or CAN/CGA B149
Installation Codes.
8. After it has been determined that each appliance
connected to the venting system properly vents where
tested as outlined above, return doors, windows,
exhaust fans, fireplace dampers and any other gas-fired
burning appliance to their previous conditions of use.
WARNING
!
EXPOSED FLAME
BEFORE OPENING BOILER DOOR, DISCON-
NECT ELECTRICAL POWER AND UNPLUG
BURNER ELECTICAL CORD. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN
INJURY, DEATH OR PROPERTY DAMAGE.
The following warning complies with State of California law, Proposition 65.
WARNING
!
HAZARDOUS GASES!
EXPOSURE TO FUEL SUBSTANCES OR BY-PRODUCTS
OF INCOMPLETE FUEL COMBUSTION IS BELIEVED BY
THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH
DEFECTS, OR OTHER REPRODUCTIVE HARM.