American Standard PFWF071A93ABA Installation Manual page 31

Oil fired water boiler with three pass cast iron heat exchanger
Table of Contents

Advertisement

Table 7
SPECIFICATIONS
MODEL
FUEL:
FIRING RATE:
EFFECTIVE OUTPUT:
VOLTAGE (Single Phase):
ABSORBED ELECTRICAL POWER: 155 Watts
MOTOR (rated):
CAPACITOR:
PUMP PRESSURE:
PRIMARY CONTROL:
IGNITION TRANSFORMER:
Models BAYRAF03ABURNA (F3)
& BAYRAF05ABURNA (F5)
5 15 / 32 "-139 mm
6 3/ 32 " - 155 mm
6 11 / 16 " - 170 mm
BAYRAF03ABURNA (F3)
NO heavier than #2 FUEL OIL
0.50 to 0.95 US GPH
70,000 to 133,000 BTU/h
120V 60Hz (+10% -15%)
3250 rpm - Run Current 2.2 AMP 3250 rpm - Run Current 2.2 AMP 3250 rpm - Run Current 2.2 AMP
12.5 Microfarads
130 to 200 psig
RIELLO 530 SE/C
8Kv 16mA
BAYRAF05ABURNA (F5)
NO heavier than #2 FUEL OIL
0.75 to 1.65 US GPH
105,000 to 231,000 BTU/h
120V 60Hz (+10% -15%)
175 Watts
12.5 Microfarads
130 to 200 psig
RIELLO 530 SE/C
8Kv 16mA
Model BAYRAF10ABURNA (F10)
5 15 / 32 "-139 mm
6 11 / 16 " - 170 mm
6 3/ 32 " - 155 mm
BAYRAF10ABURNA (F10)
NO heavier than #2 FUEL OIL
1.45 to 2.95 US GPH
203,000 to 413,000 BTU/hr
120V 60Hz (+10% -15%)
230 Watts
12.5 Microfarads
100 to 200 psig
RIELLO 530 SE/C
8Kv 16mA
18-CG03D1-4