iNSTALLATiON iNSTruCTiONS
PLumBiNg:
1. After securing tub in place, normal waste and overflow and valves are installed per normal plumbing procedures,
in accordance with all state and local standards.
2. Install standard 1-1/2" trap to drain and overflow. Before proceeding, make a final operational check by filling tub
with water to overflow and operate pump for 5 minutes. Check for leaks carefully both while pump is running and
has been turned off. Allow water to stand in tub for at least 30 minutes before draining. AquATiC iNduSTriES,
iNC. wiLL NOT BE rESPONSiBLE FOr wATEr dAmAgE OF ANy KiNd iN CONNECTiON wiTh ONE OF
Our whirLPOOL BAThS.

rOugh-iN mEASurEmENTS:

B
A
5A
10
mOdEL
LuxeAir 21
LuxeAir 22
LuxeAir 23
LuxeAir 24
LuxeAir 25
LuxeAir 26
LuxeAir 27
LuxeAir 28
LuxeAir 29
LuxeAir 30
LuxeAir 31
LuxeAir 32
LuxeAir 33
LuxeAir 34
LuxeAir 35
LuxeAir 36
LuxeAir 37
PLEASE NOTE: ThE mANuFACTurEr ACCEPTS A 1/4" VAriANCE.
VAriATiONS ON EACh TuB ANd SPECiFiCATiONS ArE SuBjECT TO ChANgE AS wE
imPrOVE uPON Our PrOduCT AS rEquirEd.
ThE dimENSiONS NEEdEd FOr SiTE PrEPArATiON ANd STruCTurE BuiLdiNg
wiLL diFFEr; AquATiC iNduSTriES, iNC. ASSumES NO rESPONSiBiLiTy FOr
PrEPArATOry wOrK.
A
(From center of overflow pipe
to outside rim)
6 1/2"
2 1/4"
5 3/8"
6 3/4"
5 1/4"
6 1/2"
2 1/4"
2 1/4"
2 1/2"
2 1/4"
1 3/4"
1 5/8"
3 1/2"
5 1/2"
3 1/2"
5 1/2"
6"
B
(From center of
drain to tub rim)
13 1/4"
12"
12"
14"
16 1/4"
13 1/2"
11 1/4"
11 1/4"
9 3/8"
10 1/2"
10 3/4"
9 1/4"
12 1/4"
13 1/2"
12 1/2"
13 1/2"
14"
ThErE ArE