LuxEAir with OPTiONAL ChrOmAThErAPy
BAThSidE CONTrOL SySTEmS:
ELECTrONiC CONTrOL PANEL
1. To Turn Air Bath System On: Pressing the on/off button
will turn the blower on in "constant mode." The light indicator
will illuminate when the system is on. The blower and the
heater will automatically shut off after a 20-minute period.
2. To Change modes: Pressing the mode button alternates
the blower modes of operation from constant mode to
wave mode and then to pulse mode.
• Constant mode: Consists of a constant blower level with
no change. when the blower is on, the indicator light is
on. when the blower is off, the indicator light is off.
• wave mode: Consists of a gradual change of blower level to generate a gentle massage effect. The light indicator
will also follow the blower intensity.
• Pulse mode: Consists of an instant change of the blower level to generate a massage effect. The light indicator
will also pulse as the blower does.
3. To Change Speeds: In constant mode, pressing and holding the "+" button will increase the variable speed of
the blower to the maximum. Pressing and holding the "—" button will reduce the blower's variable speed to the
minimum. In both cases, the user can release the button at the desired power level.
pulse mode, the "+" or "—" buttons will work the same way but will have an effect on the maximum power of the
wave and pulse mode.
4. To Turn Chromatherapy Light On: Press the light button once to turn the Chromatherapy Light on in color wash
mode. A second press of the button will turn the lighting system off. Subsequent presses will move the lighting
system through the seven constant color modes.
CAuTiON: due to the varied size, weight and shape of a person's body, water may splash out of the tub when the
air blower is on high speed. Turn the speed of the blower down using the minus button
reduce the amount of water being dispersed from the tub.
Air BATh PurgE CyCLE:
Following the 20 minute run time of the blower, there will be a 15 minute idle period. The blower will then turn on for
3 minutes for the purge cycle. If the user turns the blower off manually before the timer reaches 20 minutes, the idle
period will start after the blower has been turned off. During the 15 minute idle period and the 3 minutes purge, the
light indicator of the on/off button will blink. During the idle period, pressing the on/off button will turn on the blower in
constant mode. During the 3 minute purge, pressing the blower key will stop the purge.

AuTOmATEd dry CyCLE:

regardless if the air bath system was utilized, an automated dry cycle will turn on 20 minutes after the water
sensors do not detect water. The automated dry cycle will turn on for 3 minutes (once the sensors are dry)
to purge the air channels after any contact with water, including after a shower or cleaning/rinsing of the bath.
The two water sensors are located near the drain.
aquatic Industries, Inc.
OPErATiON of
(see Diagram 11A):
On/Off
Indicator
Mode
Decrease
Button
Light
Key
Speed
11A
Increase
Chromatherapy
Speed
Light
NOTE:
In wave mode or
to a lower setting to