9.
adjust the GREEN on OSD, until chroma 7120 indicator reached G=100
10.
adjust the BLUE on OSD, until chroma 7120 indicator reached B=100
11.
repeat above procedure ( item 8,9,10) until chroma 7120 RGB value meet the tolence
=100±2
12.
switch the chroma-7120 to xyY mode With press "MODE" button
13.
Adjust the Contrast on OSD window until the Y measurement on chroma 7120 reached
the value Y= 180 cd/m
14.
Press 78 on OSD window to save the adjustment result
b. adjust 6500 color-temperature
1
Set the Contrast of OSD function to 40, Brightness to 48
2
Switch the chroma-7120 to RGB-mode (with press "MODE" button )
3
switch the MEM.channel to Channel 06 ( with up or down arrow on chroma 7120 )
The lcd-indicator on chroma 7120 will show x = 313 ±10, y = 329 ±10, Y = 160 ±5
4
2
cd/m
5
Adjust the RED on OSD window until chroma 7120 indicator reached the value R=100
6
adjust the GREEN on OSD, until chroma 7120 indicator reached G=100
7
adjust the BLUE on OSD, until chroma 7120 indicator reached B=100
8
repeat above procedure ( item 5,6,7) until chroma 7120 RGB value meet the tolence =100
±2
9
switch the chroma-7120 to xyY mode With press "MODE" button
10 Adjust the Contrast on OSD window until the Y measurement on chroma 7120 reached
the value Y= 180 cd/m
11 Press 65 on OSD window to save the adjustment result
Turn the POWER-button off to on to quit from factory mode ( in USER-mode, the OSD window