WIKA FSM-6100 Operating Instructions Manual

WIKA FSM-6100 Operating Instructions Manual

Flow switch for industrial heat exchangers

Advertisement

Quick Links

For industrial heat exchangers
EN
Model FSM-6100
Operating instructions
Contents
Declarations of conformity can be found online at www.wika.com
© 2020 Euromisure Sas di WIKA Italia Srl
All rights reserved.
Prior to starting any work, read the operating instructions!
Keep for later use!
Euromisure Sas di WIKA Italia Srl
Via G. Borghisani 4, 26035 Pieve S.Giacomo (CR) Italy
Tel. +39 0372 6404
Fax +39 0372 640490
salesflow.it@wika.com
www.wika.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSM-6100 and is the answer not in the manual?

Questions and answers

Summary of Contents for WIKA FSM-6100

  • Page 1 7. Maintenance and cleaning 8. Dismounting, return and disposal 9. Specifications Declarations of conformity can be found online at www.wika.com © 2020 Euromisure Sas di WIKA Italia Srl All rights reserved. Prior to starting any work, read the operating instructions!
  • Page 2 2.2 Description tions prior to beginning any work. The flow element of the model FSM-6100 is a paddle which works against a spring mechanism with an adjustable pre-load force. On the spring mechanism there is a The manufacturer‘s liability is void in the case of any damage caused by using ■...
  • Page 3 3.2 Intended use they are working in and know the relevant standards and regulations. The skilled The model FSM-6100 mechanical flow switch is fitted with an SPDT switch contact electrical personnel must comply with current legal accident prevention regulations. and is used in control, monitoring and alarm applications. The switch point can be specified by the customer on site.
  • Page 4 Ensure that paddle is free to move inside the pipe and does not rub the sides. Store the instrument in its original packaging in a location that fulfils the conditions listed ■ above. Paddles assembly 1. Withdrawal of paddle 2. Tightening paddles adjoining screws Back view Front view WIKA operating instructions, flow switch, model FSM-6100...
  • Page 5 Upon contact with live parts, there is a direct danger to life ▶ The instrument may only be installed and mounted by skilled personnel. ▶ Switch off the load circuit before starting work and secure against being switched on unauthorised. WIKA operating instructions, flow switch, model FSM-6100...
  • Page 6 (not shown). Connect the must be taken out of operation immediately. model FSM-6100 flow switch, flow reference and flow generation to a common ▶ Ensure that there is no pressure in the instrument and that the load circuit flow system.
  • Page 7 Strictly observe the following when shipping the instrument: Improper cleaning may lead to physical injuries and damage to property and All instruments delivered to WIKA must be free from any kind of hazardous substances the environment. Residual media in the dismounted instrument can result in a (acids, bases, solutions, etc.) and must therefore be cleaned before being returned.
  • Page 8 37+50+80+100 2000 2650 3000 2750 3100 3200 0.5A 0.25A 0.05A 0.03A 37+50 2400 2600 3200 37+50+80 1800 1900 3200 37+50+80+100 1450 1550 3200 Above flow ranges are considered with water as medium (at density = 1000 kg/m³, pressure = 1 atm, temperature = 25 ⁰ C) WIKA operating instructions, flow switch, model FSM-6100...

Table of Contents