the switch is off.
Failover: turn on to protect your NDI transmission from failure. If the initial
source video fails, the backup device begins to provide a service. The initial
source will be automatically switched back to after it recovers. This function
is disabled by default.
Source name shows the backup NDI channel name.
Click Change... and select the failover (backup) video device within the
same NDI group as the initial source.
IP Address shows the IP Address of the backup NDI channel which is
automatically obtained after you select the backup NDI source.
Receiver Control: turn on Web control to enable you to open the Web UI
by clicking the gear icon in the NDI Studio Monitor application.
Only 1 NDI streaming session can be started each time, but you can add
multiple servers to the streaming server list.
When live streaming to NDI server, the encoder would send the main and
sub streams simultaneously.
You can push NDI over sub stream at the following encode profile:
Resolutions: 640x480, 640x360
Frame rate: 60, 59.94, 50, 30, 29.97, 25, 24, 15, 10, 5fps. To ensure
smooth viewing experience, the frame rate above 29.97fps is
recommended.
Max bitrate: 2 Mbps