Feature
Reminder
Factory default
OFF
settings
This feature will
flash FILT in
the display after
the elapsed run
time to remind
Feature
the user to
Description
change the filter.
A setting of OFF
will disable this
feature.
LCD will show
Room
Minimum
Temperature
Compressor On
Calibration
Time
0°F
OFF
This feature
This feature allows
allows the
the installer to select
installer to
the minimum
change the
run time for the
calibration of the
compressor. For
room
example: A setting of
temperature
4 will force the
display. For
compressor to
example, if
run for at least 4
the thermostat
minutes every time
reads 70°F and
the compressor
you would like
turns on, regardless
it to read 72°F
of the room
then select +2.
temperature.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
TECHNICIAN SETUP MENU
Compressor
Cooling
Short Cycle
Differential or
Swing
Delay
On
0.5°F
The
The differential
compressor
setting often
short cycle
called cycle rate
delay protects
or anticipation is
the compressor
adjustable.
from short
A smaller
cycling. This
differential
feature will not
setting will cause
allow the
more frequent
compressor to
cycles and a
be turned on
larger differential
for 5 minutes
setting will cause
after if was last
fewer cycles.
turned off.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
Heating
Differential or
Swing
0.4°F
The
differential
setting, often
called cycle rate
or anticipation
is adjustable.
A smaller
differential setting
will cause more
frequent cycles
and a larger
differential setting
will cause fewer
cycles.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
9