Filter Change
Feature
Reminder
Factory default
OFF
settings
This feature will
flash FILT in
the display after
the elapsed run
time to remind
Feature
the user to
Description
change the filter.
A setting of OFF
will disable this
feature.
LCD will show
Room
Minimum
Temperature
Compressor On
Calibration
Time
0°F
OFF
This feature
This feature allows
allows the
the installer to select
installer to
the minimum
change the
run time for the
calibration of the
compressor. For
room
example: A setting of
temperature
4 will force the
display. For
compressor to
example, if
run for at least 4
the thermostat
minutes every time
reads 70°F and
the compressor
you would like
turns on, regardless
it to read 72°F
of the room
then select +2.
temperature.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
TECHNICIAN SETUP MENU
Compressor
Cooling
Short Cycle
Differential or
Swing
Delay
On
0.5°F
The
The differential
compressor
setting often
short cycle
called cycle rate
delay protects
or anticipation is
the compressor
adjustable.
from short
A smaller
cycling. This
differential
feature will not
setting will cause
allow the
more frequent
compressor to
cycles and a
be turned on
larger differential
for 5 minutes
setting will cause
after if was last
fewer cycles.
turned off.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
Heating
Differential or
Swing
0.4°F
The
differential
setting, often
called cycle rate
or anticipation
is adjustable.
A smaller
differential setting
will cause more
frequent cycles
and a larger
differential setting
will cause fewer
cycles.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
9
Table of
Contents
Previous
Page
Next
Page
1
...
8
9
10
11
12
13
14
15
Advertisement
Related Manuals for Robertshaw RS8210
Thermostat Robertshaw RS8210 Installation Manual
(24 pages)
Thermostat Robertshaw RS8210 Installation Manual
(24 pages)
Thermostat Robertshaw RS8210 Operation Manual
(16 pages)
Thermostat Robertshaw RS8110 Installation Manual
(20 pages)
Thermostat Robertshaw RS8110 Operation Manual
(12 pages)
Thermostat Robertshaw RS8110 Installation Manual
(20 pages)
Thermostat Robertshaw RS8110 Operation Manual
(12 pages)
Thermostat Robertshaw RS4110 User Manual
Single/two/three stage (25 pages)
Thermostat Robertshaw Rs 4110 User Manual
(25 pages)
Thermostat Robertshaw RS6110 User Manual
Programmable thermosta (33 pages)
Thermostat Robertshaw RS5220C User Manual
Programmable (33 pages)
Thermostat Robertshaw RS9220 Installation Manual
(28 pages)
Thermostat Robertshaw RS9110 Operation Manual
(21 pages)
Thermostat Robertshaw RS9110 Operation Manual
(20 pages)
Thermostat Robertshaw RS9210 Installation Manual
(28 pages)
Thermostat Robertshaw RS10420T Installation Manual
(32 pages)
Related Products for Robertshaw RS8210
Robertshaw RS8110
Robertshaw RS4220
Robertshaw RS6220
Robertshaw RS5220
Robertshaw RS4320
Robertshaw RS6320
Robertshaw RS6320C
Robertshaw RS4320C
Robertshaw RS4220C
Robertshaw RS7210
Robertshaw RS9110
Robertshaw RS9210
Robertshaw RS6000
Robertshaw RS6220C
Robertshaw RS4000C Series
Robertshaw RS6000C Series
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL