Thank you for purchasing a Robertshaw RS4000 thermostat. This user's
manual will guide you through the setup of the RS4110 single stage, the
RS4220 two stage, and the RS4320 three stage* thermostats. The
thermostat should already be mounted and correctly wired. The default
settings will enable the thermostat to operate efficiently.
Features
• Pop-Up Wizard
• Automatic changeover
• Circulating Fan
• Worry-Free memory retention
• Easy change battery
• Large back lit display
• Filter change reminder
• Low battery indicator
• Fahrenheit and Celsius displays
• Dual power
• Adjustable 1
to 1.5 °C)
• Accuracy within ±1 °F
• Universal staging on multi-stage units
• Automatic heating shutdown if temperature exceeds 99 °F (37 °C)
• Keypad security lockout
• User settable Hi and Lo temperature limits
* Three stage heating available for heat pump applications only.
USERS MANUAL
st
stage temperature differential: 0.5 °F to 3.0 °F (0.5 °C
RS
RS
RS
1
4110
4220
4
20
3
352-00055-001 Rev B

Advertisement

Table of Contents
loading

Summary of Contents for Robertshaw RS4110

  • Page 1 USERS MANUAL Thank you for purchasing a Robertshaw RS4000 thermostat. This user’s manual will guide you through the setup of the RS4110 single stage, the RS4220 two stage, and the RS4320 three stage* thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently.
  • Page 2 The Robertshaw 4000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS4110 is a single stage thermostat while the RS4220 is a two stage thermostat. The RS4320 can support three stages of heating and two stages of cooling in heat pump applications.
  • Page 3: Installing Or Changing The Batteries

    Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides. The battery compartment will pull down from the thermostat body and will detach. Install two AA batteries following the polarity as shown inside the compartment. Place compartment back into the thermostat.
  • Page 4: Emergency Heat

    User Settings – Defaults During any program changes the display returns back to the operating display if a button has not been pushed in 10 seconds. The temperature scale is set to Fahrenheit. Night light is on. The first stage differential is 1 °F. The second stage differential (RS4220) is 2 °F.
  • Page 5: Operating The Thermostat

    Operating the Thermostat Any setting can be changed when it is flashing by pushing If a button is not pushed for 10 seconds the thermostat returns to operation. The following buttons can be accessed from the front panel. LIGHT BAR: Turns on the display back light for 10 seconds. FAN: Turns fan to AUTOMATIC, CIRCULATE or ON.
  • Page 6 dF = The differential keeps the thermostat from turning on for small changes in temperature. When in Fahrenheit the range is 0.5 to 3.0 Degrees. In Celsius the range is 0.5 to 1.5 Degrees. The differential is factory set at 1.0 °F (0.5 °C). This means that whenever the room temperature is more than 1 °F (0.5 °C) different from the set temperature the system will turn on.
  • Page 7 Auto changeover enable = Makes the auto changeover mode available. When chosen, the user can select auto changeover mode which automatically switches between heating and cooling. Note that the High and Low setpoint limits are not enforced in auto changeover mode. db = Deadband for auto changeover = the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for.
  • Page 8 CY = Cycle Timer allows a compressor to rest between cycles. Can be set from 0 to 5 minutes in 1 min increments. WARNING: A wrong short cycle setting can damage your equipment. This should only be changed by a trained HVAC professional. CL = Calibration offset.
  • Page 9: Backlit Display

    Two Stage Systems A 2nd stage is a second or additional system that will provide extra heating or cooling. When a 2nd stage is operating the display will show the number 2 by the heat/cool icons. A temperature differential (default value is 2.0 °F or 1.0 °C) and time delay (default value 20 minutes) control the 2nd stage cycle.
  • Page 10: Troubleshooting

    Troubleshooting Problem Action Check wiring. Thermostat does not turn on system. (See Wiring Diagrams section.) Increase temperature differential. (See Changing: Scale, Clock Mode, System turns on too often. Differential, Filter Hours, Short Cycle, or Offset section.) Move fan option switch to either gas System fan does not operate properly.
  • Page 11: Five Year Limited Warranty

    Five Year Limited Warranty Invensys Controls warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of Five (5) years from date of purchase. This...
  • Page 12 NOTES 515 South Promenade Avenue Corona, CA 92879-1736 United States of America www.invensyscontrols.com ©2008 Invensys Controls 2/08 352-00055-001 Rev B...
  • Page 13: Manual Del Usuario

    MANUAL DEL USUARIO Gracias por comprar un termostato programable Robertshaw Serie RS4000. El manual le ayudará a programar el modelo RS4110 de una sola etapa, el modelo RS4220 de dos etapas y el modelo RS4320 de tres etapas*. El termostato debe estar instalado y conectado adecuadamente a la red de electricidad.
  • Page 14 La familia de termostatos Robertshaw 4000 está diseñada para controlar sistemas de refrigeración eléctrica y de calefacción de gas, electricidad, petróleo, bombas de calor y minivolt. El modelo RS4110 es un termostato de una sola etapa y el RS4220 es un termostato de dos etapas.
  • Page 15 Para instalar o cambiar las pilas Para retirar el compartimiento de las pilas, apriete suavemente los bordes estriados de ambos lados. El compartimiento de pilas de desprenderá del cuerpo del termostato. Coloque dos pilas AA según la indicación de polaridad que figura en el interior del compartimiento.
  • Page 16 Ajustes del Usuario – Valores por defecto Durante cualquier cambio en la programación, el visor vuelve al modo operación si no se presiona ninguna tecla durante 10 segundos. La escala de temperaturas está en grados Fahrenheit. Luz de noche encendida. El diferencial de primera etapa es 1 ºF.
  • Page 17 Cómo operar el termostato Cuando los valores programados titilan se pueden modificar presionando las teclas Si no se pulsa ninguna tecla en 10 segundos, el termostato vuelve a ponerse en funcionamiento. Puede acceder a las siguientes teclas desde el panel delantero. LIGHT BAR (BARRA DE ILUMINACIÓN): ilumina el visor durante 10 segundos.
  • Page 18 dF = el diferencial evita que el termostato se ponga en funcionamiento ante cambios muy pequeños de temperatura. Si está programado en la escala Fahrenheit, el rango de oscilación es de 0.5 a 3.0 grados. Si está programado en la escala Celsius, el rango de oscilación es de 0.5 a 1.5 grados.
  • Page 19 dL E2 = retardo de la tercera etapa = este timer arranca cuando la segunda etapa está conectada. Se repone cuando se apaga la segunda etapa. Si este timer termina su tiempo, se conectará la tercera etapa. Disponible solamente en RS4320. (Ver Sistemas de Tres Etapas).
  • Page 20 LO = límite inferior de temperatura = este es el punto de ajuste más bajo permitido en refrigeración. El usuario no podrá fijar un punto de ajuste inferior a este valor. Nota: En el modo conmutación automática no se respeta el Low Cool Limit (Límite Inferior de Refrigeración).
  • Page 21 Cómo crear una contraseña – Proteja los ajustes Las teclas que aparecen en la parte delantera del termostato pueden bloquearse con una contraseña. Para crear una contraseña: 1. Pulse las teclas simultáneamente durante 5 segundos. Se le pedirá que ingrese una contraseña de cuatro dígitos. 2.
  • Page 22: Cierre Automático

    Sistemas de tres etapas Una tercera etapa es un tercer sistema o sistema adicional que proporcionará calefacción extra en las aplicaciones con bomba de calor. Cuando la 3er etapa está en operación el visor mostrará el número 2 y la letra E en el icono de calor. Un retardo de tiempo (el valor por defecto es 20 minutos) controla el ciclo de la tercera etapa.
  • Page 23: Resolución De Problemas

    Resolución de problemas Problema Solución Verifique el cableado. El termostato no pone en funcionamiento (Ver sección Diagramas de cableado en el sistema. el Manual de Instalación.) Aumente el diferencial de temperatura. El sistema se pone en funcionamiento (Ver sección Para cambiar la muy pronto.
  • Page 24 Garantia Limitada de 5 años Invensys Control garantiza al instalador contratista original o al usuario original que cada termostato Robertshaw nuevo no tendrá defectos en componentes ni en construcción con el uso y mantenimiento normal durante un período de cinco (5) años desde la fecha de la compra. Esta garantía y nuestra responsabilidad no se aplican a las pilas ni a los...