Summary of Contents for Adesso NuScan 2100 Series

  • Page 1 Part No. : MUL-53221-07...
  • Page 2 PROGRAMMING GUIDE BARCODE SCANNERS The guide can be used as keyboard emulation, RS- 232C serial interface, and USB 1.1 interface and wand emulation.
  • Page 3: Table Of Contents

    IMPORTANT NOTICE This is a general guide for varies scanners, and not all functions will perform in every scanners. Other than specified in this guide, for any special functions or specifications, please contact your dealer for details. Every effort is made to ensure the accuracy of our product information;...
  • Page 4: Introduction

    IBM PC/XT/AT, PS/2 or any fully compatible computers, power will be drawn from the keyboard port. No external power adapter is required. emulation type scanner is used with any other non IBM PC compatible computers, an external power adapter may be needed.
  • Page 5: Default Parameters

    This table gives the default settings of all the programmable parameters. The default settings will be restored whenever the "Reset" programming label is scanned and the laser scanner is in programming mode. DEFAULT VALUES OF OPERATING PARAMETERS Function Scanning Mode Selection...
  • Page 6: Program Procedure

    DEFAULT VALUES OF DECODING PARAMETERS Function Code Code 39 ITF 2 of 5 Chinese Post Code UPC/EAN/JAN Coda bar Reading codes ※ Selection Code 128 Code 93 ※ ITAT ※ EAN-128 ※ MATRIX 25 ※ Italian Pharmacy ISSN/ ISBN Codes Start/stop characters Not transmitting Code 39 Check digit...
  • Page 7: System Setting

    • The reading of the "ABORT" label discards ABORT parameters read prior to the "End of configuration". • The scanner remains in the last interface mode when RS-232C the scanner is reset. The label below scanned if the scanner is PC/AT configured the first time.
  • Page 8: General Configuration

    SCANNING MODE SELECTION (For CCD scanner) The scanner becomes inactive as soon as the data is transmitted. It must be triggered to become active again. In auto scan mode, the scanner is still active after data transmitted, but the successive...
  • Page 9: Inter-Message Delay

    A block of message will only be transmitted after a “Send” command is entered. This mode is only available when the scanner is working with code 39 labels. character as the “ Send” command.
  • Page 10: Beeper Tone Selection

    Start of Configuration SEND COMMAND IN BLOCK MODE COMMUNICATION You can use this option to set your own “Send” command used in block mode communication. Enable Disable Store GOOD READ BEEPER TONE SELECTION You can use this option to set frequency and / or duration of the buzzer after successful reading.
  • Page 11: Interface Configuration

    CONFIGURATION Start of Configuration 1. RS-232C SERIAL COMMUNICATION PARAMETERS SETTING The RS-232C scanner supports four handshaking protocols. With these options of communication protocol, you can tailor the scanner to meet the requirement of most systems HANDSHAKING PROTOCOL None RTS/CTS ACK/NAK...
  • Page 12: Baud Rate

    Start of Configuration ACK/NAK RESPONSE TIME SETTING (Cont’d) 3 sec 1 sec 5 sec BAUD RATE 19200 9600 4800 2400 1200 DATA BIT STOP BIT PARITY Even Mark Space None End of Configuration...
  • Page 13: Message Terminator

    Keyboard emulation is activated whenever you have selected the type of keyboard for which the scanner is going to emulate. Choose the appropriate type of keyboard emulation by scanning the labels under the following labels.
  • Page 14: Language Selection

    Start of Configuration KEYBOARD TYPE SELECTION (Cont’d) NEC 9801 IBM 3196 Terminal APPLE MAC II( ※ ) IBM 3477/3472 Terminal PS2/30/56 IBM 3477 Terminal (Without break code) NEC 5200( ※ ) Note: The configuration of the items with asterisk ( ※ ) is optional.
  • Page 15: Message Terminator

    Start of Configuration MESSAGE TERMINATOR (FOR KEYBOARD WEDGE USE) None Return /Enter Hor. TAB Execute KEYBOARD TYPE SELECTION Scan Code Mode Alt mode BREAK CODE Terminals 31xx, 34xx, 37xx USE) To select the interface for these IBM terminals, read the correct key transmission code.
  • Page 16: Wand Emulation Parameters Setting

    Start of Configuration 00H~1FH ASCII Code defined Alt-mode code Crtl+code 3. WAND EMULATION PARAMETERS SETTING EMULATION SPEED SELECTION Medium Normal High Higher EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit the external decoder. Black = High Black = Low WAND EMULATION NARROW/WIDE RATIO...
  • Page 17: Usb Interface Parameters Setting

    Start of Configuration 4. USB INTERFACE PARAMETERS SETTING The USB mode is effectively a keyboard emulator that works with hosts that USB-compatible operating system and USB ports. USB compatible operating systems are Windows 98, Windows NT 5.0 and later, no additional software is needed since the USB driver support is built into this operating system.
  • Page 18: Reading Code Selection

    Start of Configuration READING CODE SELECTION Code 39 Enable Code 39 Disable Coda bar Enable Coda bar Disable UPC/ EAN/ JAN Enable UPC/ EAN/ JAN Disable ITF 2 of 5 Enable ITF 2 of 5 Disable Chinese Post Code Enable Chinese Post Code Disable Code 128 Enable Code 128 Disable...
  • Page 19: Code 39 Parameters Setting

    Start of Configuration READING CODE SELECTION (Cont’d) Italian Pharmacy Enable Italian Pharmacy Disable CODE 39 PARAMETERS SETTING CHARACTER SET Standard Code 39 Full ASCII Code 39 START/STOP CHARACTER TRANSMISSION CHECK DIGIT Calculate and Transmit Calculate but not Transmit CONCATENATION Enable Disable INTERLEAVED 2 OF 5 PARAMENTERS SETTING Examples: Felting length 4 to 8 digits...
  • Page 20: Chinese Post Code Parameters Setting

    Start of Configuration CHECK DIGIT Calculate and Transmit Calculate but not Transmit CHINESE POST CODE PARAMETERS SETTING LENGTH Scan:. Start of configuration UPC/EAN/JAN PARAMETERS SETTING End of configuration CHECK DIGIT Calculate and Transmit Calculate but not Transmit FORMAT EAN-8 or EAN-13 UPC-A and EAN-13 UPC-A and UPC-E UPC-A...
  • Page 21 Start of Configuration UPC/EAN/JAN PARAMETERS SETTING (Cont’d) EAN-13 EAN-8 ADDENDUM 5 Characters 2 Characters 2 or 5 Characters FORCE UPC-E TO UPC-A FORMAT FORCE UPC-A TO EAN-13 FORMAT TRANSMIT UPC-A LEADING CHARACTER TRANSMIT UPC-A CHECK DIGIT TRANSMIT UPC-E LEADING CHARACTER End of Configuration...
  • Page 22: Codabar/ Monarch Parameters Setting

    Start of Configuration TRANSMIT UPC-E CHECK DIGIT TRANSMIT EAN-13 CHECK DIGIT TRANSMIT EAN-8 CHECK DIGIT CODABAR/ MONARCH PARAMETERS SETTING START/ STOP CHARACTER TRANSMISSION A, B, C, D DC1~DC4 a/ t, b/ n, c/ *, d/ e CONCATENATION Enable Disable CODE 128 PARAMETERS SETTING FNC 2 CONCATENATION Enable Disable...
  • Page 23: Matrix 25 Parameters Setting

    Start of Configuration CODE 128 PARAMETERS SETTING (Cont’d) CHECK DIGIT Calculate but not Transmit Calculate and Transmit UCC/EAN128 PARAMETERS SETTING The character FNC1 can be transmitted or not using these codes. FNC1 Character Transmitted FNC1 not Transmitted MATRIX 25 PARAMETERS SETTING Examples: Felting length 4 to 8 characters Scan.
  • Page 24: Italian Pharmacy Parameters Setting

    Start of Configuration MSI/PLESSY PARAMETERS SETTING (Cont’d) PLESSY CODE SETTING Calculated and transmitted Calculate but not transmitted CHECK DIGHT Calculate and Transmit Calculate but not Transmit ITALIAN PHARMACY PARAMETERS SETTING TRANSMIT "A" CHARACTER BARCODE LENGTH SETTING CODE 39 LENGTH SETTING CODE 93 LENGTH SETTING CODE 128 LENGTH SETTING CODABAR LENGTH SETTING...
  • Page 25: Isbn/ Issn Conversion

    Start of Configuration ISBN/ ISSN CONVERSION The function convents the UPC/EAN codes appearing on books and magazine not ISBN/ISSN format. ACTIVE ISBN/ ISSN INACTIVE ISBN/ ISSN DATA EDITING End of Configuration...
  • Page 26: Header And Trailer

    Start of Configuration HEADER AND TRAILER This option allows you to append a header and/or a trailer to every message transmitted via the serial ports or the keyboard port. There is no restriction in selecting header or trailer characters as far as the sum of the lengths of header and trailer is not greater than 10 digits.
  • Page 27: Truncate Header/Trailer Character

    Start of Configuration BARCODE IDENTIFIER CODE SETTING (Cont’d) Codabar Code 39 Code 128 Code 93 MATRIX 25 Truncate Header/Trailer Character (Version az1.24, dz1.05 , ac1.01, dz1.05,pl1.39 Or higher is required) You can truncate a number header or trailer for a symbology.
  • Page 28: Appendixes

    APPENDIXES APPENDIX A CODE 39 FULL ASCII CODE TABLE CODE VALEUR ASCII ASCII HEXA. & < > " APPENDIX A CODE VALEUR HEXA.
  • Page 29 CODE 39 FULL ASCII CODE TABLE CODE VALEUR ASCII ASCII HEXA. APPENDIX A UNCTION K CODE VALEUR HEXA. Enter(num) APPENDIX B EY EM ULATI N NCTI CODE ASCII H ome Down Left Backspace Right PgUp Enter PgDn Ctl(L) shift Alt(L) 5 (num) CODE ASCII...
  • Page 30: Code 39 Full Ascii Barcode Table

    CODE 39 FULL ASCII BARCODE TABLE Start of Configuration (Ins) (Del) (Home) (End) APPENDIX B CODE 39 FULL ASCII BARCODE TA (Up) (L t) (Backspace) (TAB) (Enter)(num) 5 (num) (Right) (F1) (PgUp) (F2) (Enter) (F3) (PgDn) (F4) shift(L) (F5) End of Configuration...
  • Page 31 APPENDIX B CODE 39 FULL A CII BARCODE TABLE art of Configur ation (F6) (F7) (F8) (F9) (F10) (F12) APPENDIX B CODE 39 FULL ASCII BARCODE TABLE (ESC) Ctl (L) Alt (L) " & End of Configuration...
  • Page 32 APPENDIX B CODE 39 FULL A CII BARCODE TABLE Start of Configuration APPENDIX B CODE 39 FULL ASCII BARCODE TABLE < > End of Configuration...
  • Page 33 APPENDIX B CODE 39 FULL A CII BARCODE TABLE Start of Config ration APPENDIX B CODE 39 FULL A CII BARCODE TA End of Configuration...
  • Page 34 APPENDIX B CODE 39 FULL A CII BARCODE TABLE Start of Configu tion APPENDIX B CODE 39 FULL A CII BARCODE TA APPENDIX C End of Configuration...
  • Page 35: Appendix C Barcode Samples

    BARCODE SAMPLES Code 39 Code 128 C O D E Interleaved 2 of 5 1 2 3 4 5 6 7 8 9 0 Coda bar(NW-7) A $ 9 9 . 9 5 A UPC A 4 4 2 5 2 3 0 2 4 5 EAN-13 4 7 1 1 2 3 4 5 6 7 8 9 9 APPENDIX D...

This manual is also suitable for:

Nuscan 1000